摘要 目的:提高输液泵质量控制检测水平。方法:采用Infutest 2000E型输液泵检测仪在不同条件下对输液泵进行检测实验和对比测试,提出输液泵临床应用质量控制检测概念。结果:针对非专用输注管路进行的输液泵标定是有效和重要的。结论:只有把输液泵临床应用质量控制检测作为输液泵质量安全评价的关键依据,才能确保输液泵临床应用的质量安全。 ObjectiTe To improve the quality control testing level of the infusion pump.Methods Infutest 2000E was used to do detection experiments and comparative tests to the infusion pumps under different conditions,and the quality control testing concept of the infusion pump clinical application was proposed.Results The infusion pump calibration for nondedicated infusion pipeline was valid and important.Conclusion Only quality control testing of the infusion pump clinical application is regarded as the key basis of the quality and safety evaluation of infusion pumps,the quality and safety of the infusion pump clinical application will be ensured.
机构地区 解放军
出处 《医疗卫生装备》 CAS 2012年第3期111-113,共3页 Chinese Medical Equipment Journal
关键词 输液泵 质量控制 质量安全 临床应用 infusion pump quality control quality safety clinical application
  • 相关文献

参考文献4

  • 1黄燕,种银保,初继庆,朱彬.医院输液泵质量控制检测与体会[J].医疗卫生装备,2010,31(11):134-136. 被引量:10
  • 2于树滨.医用输液泵、注射泵质量控制检测技术[M].北京:中国计量出版社,2010:13.
  • 3GB 8368—2005一次性输液器标准[S].
  • 4GB 9706.27—2005/IEC 60601-2-24:1998医用电气设备第2-24部分:输液泵和输液控制器安全专用要求[S].