期刊文献+

ICP-MS法测定注射用双黄连(冻干)无机阳离子的含量 被引量:1

Determination of content of trace elements in Shuanghuanglian injection by ICP-MS
下载PDF
导出
摘要 注射用双黄连(冻干)样品经微波消解后,利用电感耦合等离子体质谱(ICP-MS)测定其中B、Al、V、Cr、Mn、Fe、Co、Ni、Cu、Zn、As、Cd、Ba、Hg等15种微量元素的含量。结果表明,方法回收率为81.6%~96.3%,检出限为0.001~1.53 ng/g,方法快捷、准确、灵敏度高,可以用于注射用双黄连(冻干)的微量元素的测定,同时也进一步完善了注射用双黄连(冻干)无机元素分析,为其质量控制提供了参考依据。 ICP-MS method was used to determine the contents of 15 trace elements such as B,Al,V,Cr,Mn,Fe,Co,Ni,Cu,Zn,As,Cd,Ba,Hg and Pb after the trace elements digestion.Results showed the contents of poisonous elements including Cu,Cd,Hg,Pb and As conformed to the standard of FDA.The recovery was 81.6%~96.3%,the LOD was 0.001~1.53 ng/g.The method is fast,accurate,sensitive and applicable for determination of trace elements in Shuanghuanglian injection.The results provided valuable data for further investigating the composition of inorganic elements in Shuanghuanglian injection and improving the standard control for its quality.
出处 《应用化工》 CAS CSCD 2012年第3期522-524,共3页 Applied Chemical Industry
关键词 注射用双黄连(冻干) ICP-MS 微量元素 Shuanghuanglian injection ICP-MS trace elements
  • 相关文献

参考文献3

二级参考文献79

  • 1田柱萍,何邦平,王小燕,林锦明.中药材的药效与其所含微量元素关系的研究进展[J].微量元素与健康研究,2005,22(4):54-56. 被引量:107
  • 2Grenville Holland. Plasma Source Mass Spec-trometry : New Developments and Applications. Cambridge : Royal Society of Chemistry,1999,299.
  • 3Grenville Holland,Scott D Tanner. Plasma Source Mass Spectrometry: the New Millennium. Cambridge : Royal Society of Chemistry, 2001,427.
  • 4Howard E Taylor. Inductively Coupled Plasma-Mass Spectrometry : Practices and Techniques,San Diego : Academic Press, 2001, 294.
  • 5Akbar Montaser. Inductively Coupled Plasma Mass Spectrometry,New York : J. Wiley, 1998,964.
  • 6Roy W Morrow, Jeffrey S Crain. Applications of Inductively Coupled Plasma-Mass Spectrometry to Radionuclide Determinations. West Conshohocken, Pennsylvania : ASTM, c1998, 145.
  • 7Roy W Morrow, Jeffrey S Crain. Applications of Inductively Coupled Plasma-Mass Spectrometry to Radionuclide Determinations. West Conshohocken, Pennsylvania: ASTM, c1995, 145.
  • 8Wangzhao Zhu. Advanced Inductively Coupled Plasma Mass Spectrometry Analysis of Rare Earth Elements. Environmental Applications,Rotterdam : Balkema, 1999,157.
  • 9Narong Praphairaksit, R S Houk. Attenuation of Matrix Effects in Inductively Coupled Plasma Mass Spectrometry with a Supplemental Electron Source inside the Skimmer. Analytical Chemistry, 2000, 72(11): 2351~2355.
  • 10Scott D Tanner, Lisa M Cousins, Douglas DJ. Reduction of Space Charge Effects Using a Three-Aperture Gas Dynamic Vacuum Interface for Inductively Coupled Plasma-Mass Spectrometry. Appl. Spec., 1994,48 (11).