摘要
介绍在柳钢转炉厂150t系统实施的调整风机转速、修正含水率设定值、调节二文喉口开度等提高煤气回收量的措施及其效果。
The countermeasures for improving the recovery amount of converter gas, such as to adjust the fan speed, amend the setting value of moisture content, adjust the throat opening of the second Venturi and so on, and its effects applied for 150 t System of Converter Plant in Liuzhou Steel were introduced.
关键词
转炉
煤气回收
风机转速
水率
二文喉口开度
Converter Furnace
Gas Recovery
Fan Speed
Moisture Content
Throat Opening ofthe Second Venturi