利用DRASTIC模型和MAPGIS叠加技术,并采用层次分析法,构建地下水脆弱性评价系统,将该评价系统应用于邢台市山前倾斜平原区孔隙水脆弱性评价。结果表明,评价结果与实际情况比较吻合。
The DRASTIC model and the superposition technique of MAPGIS were employed to construct the groundwater vulnerability assessment system using the analytic hierarchy process method.This system was applied to the assessment of vulnerability of pore water in the piedmont sloping plain in Xingtai City.The results show a good agreement with the actual situation.