摘要
基于异频法的原理和参数测试方法,对现有4种不同测试频率的异频法进行分析和比较,从算法上分析了异频法产生的误差,并对3种工况进行仿真测试和验证,根据不同测试条件下的误差变化趋势给出适用的测试频率。
This paper analyzes and compares four kinds of non-power frequency measuring methods based on the theo- ry of non-power frequency measuring method and electrical parameters test method. And the cause of non-power frequen cy measuring error is analyzed. The methods are verified and simulated under three testing conditions. Finally, applicable of test frequency is obtained on the basis of error change trend in different conditions.
出处
《水电能源科学》
北大核心
2012年第4期159-163,共5页
Water Resources and Power
关键词
线路参数测量
异频法
参数非线性
正序阻抗
零序阻抗
lines parameter measurement
non-power frequency method
parameter nonlinearity
positive sequence impedance
zero sequence impedance