期刊文献+

寰椎椎板钩枢椎椎弓根螺钉加钛缆治疗小儿寰枢椎脱位的疗效观察 被引量:2

Application of C1 hook and C2 isthmic screws combined with titanium cable in the treatment of atlantoaxial dislocation in children
原文传递
导出
摘要 目的评估后路寰椎椎板钩枢椎椎弓根螺钉加钛缆固定治疗小儿寰枢椎脱位的手术治疗方法,讨论小儿寰枢椎脱位的诊断及治疗。方法对7例寰枢椎脱位伴齿突骨折的患儿行后路寰椎椎板钩枢椎椎弓根螺钉加髂骨植骨钛缆固定术。术前均行X线片、CT等影像学检查;术中在直视下行寰椎置椎板钩,枢椎椎弓根螺钉,钛棒连接,复位,髂骨植骨钛缆固定。术后颈托固定1个月。结果所有螺钉均成功置入,复位固定满意,植骨全部融合,无鹅颈等发育性畸形出现。结论后路寰椎椎板钩枢椎椎弓根螺钉加钛缆固定具有术中复位满意、固定牢靠、融合率高等特点,为寰枢椎脱位患儿治疗提供了一种较好的内固定术式。 Objective To evaluate clinical outcome of C1 hook and C2 isthmic screws combined with titanium cable in the treatment of atlantoaxial dislocation in children and both diagnosis and treatment were discussed.Methods Seven children of atlantoaxial dislocation were analyzed retrospectively after they were treated with posterior iliac bone graft,fixation of C1 hook and C2 isthmic screws combined with titanium cable and postoperative cervical gear fixation for one month.Results All patients had bony fusion and no developmental abnormalilities such as gooseneck existed.Conclusions The fixation of C1 hook and C2 isthmic screws combined with titanium cable is easy and safe.It provides good fixation leading to high rate of graft fusion.It can be a good choice of the treatment of atlantoaxial dislocation in children.
出处 《中华临床医师杂志(电子版)》 CAS 2012年第4期I0012-I0014,共3页 Chinese Journal of Clinicians(Electronic Edition)
关键词 儿童 寰枢椎脱位 椎板钩 椎弓根螺钉 脊柱融合 Child Atlantoaxial dislocation Laminar hooks Isthmic screws Spinal fusion
  • 相关文献

参考文献2

二级参考文献17

  • 1马向阳,尹庆水,吴增晖,夏虹,钟世镇,刘景发,徐达传.寰椎椎弓根与枢椎侧块关系的解剖与临床研究[J].中华骨科杂志,2004,24(5):295-298. 被引量:86
  • 2谭明生,移平,王文军,谭远超,张恩中,韦宏宇,杨峰,蒋欣.经寰椎“椎弓根”螺钉内固定技术的临床应用[J].中国脊柱脊髓杂志,2006,16(5):336-340. 被引量:103
  • 3樊健,赵剑,邵菁菁,刘璠,管国平,邵云伟,张辉,王以进.颈椎前路静力性与动力性钉板系统在三柱不稳定损伤中生物力学性能的比较[J].中国骨与关节损伤杂志,2007,22(4):265-267. 被引量:7
  • 4Richter M, Schmidt R, Claes L, et al. Posterior atlantoaxial fixation: hiomechanical in vitro comparison of six different techniques. Spine, 2002, 27:1724
  • 5Hanley EN, Harvell JC. Immediate postoperative stability of the atlantoaxial articulation: a biomechanical study comparing simple midline wiring and the gallic and brooks procedures. J Spinal Disord, 1992, 5 : 306
  • 6Gallic W. Fractures and dislocations of the cervical spine. Am J Surg, 1939, 46:495
  • 7Kandziora F, Kerschbaumer F, Starker M, et al. Biomechanical assessment of transoral plate fixation for atlantoaxial instability. Spine, 2000, 25:1555
  • 8Herring JA, Wenger DR. Segmental spinal instrumentation: a preliminary report of 40 consecutive cases. Spine, 1982, 7:285
  • 9Naderi S, Crawford NR, Song GS, et al. Biomechanical comparison of C1 - C2 posterior fixations: cable, graft, and screw combination. Spine, 1998, 23:1946
  • 10Resnick D K,Benzel E C.C1-C2 pedicle screw fixation with rigid cantilever beam construct: case report and technical note. Neurosurgery . 2002

共引文献12

同被引文献14

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部