期刊文献+

海水中铜、铅、镉、锌国标测定条件优化 被引量:3

Optimization of Conditions in Determination Method of Cu,Pb,Zn,Cd in Sea Water
下载PDF
导出
摘要 对海水中铜、铅、镉、锌国标测定方法进行了条件优化,研究了冲洗溶液、萃取溶剂、络合剂、pH、提取量对实验结果的影响,在优化条件下,铜、铅、镉、锌测定的相对标准偏差在0.0%~2.0%之间,标样测定结果均优于等离子发射光谱法等4种方法. In this paper,conditions in the determination method of Cu,Pb,Zn,Cd in sea water were optimized,the effects of rinsing solvent,extraction solvent,chelating agent,pH,and uptake rate on the determiantion results were studied.Under optimized conditions,the relative standard deviations(RSDs) of Cu,Pb,Zn,Cd are in the range of 0.0%~2.0%.The determination results of standard samples are better than that of GB17378.4-2007,ICP-AES and Polarographic methods.
出处 《分析测试技术与仪器》 CAS 2012年第1期57-61,共5页 Analysis and Testing Technology and Instruments
关键词 海水 重金属 无火焰原子吸收 等离子发射光谱 sea water heavy metals non-flame atom absorption ICP-AES
  • 相关文献

参考文献7

二级参考文献4

  • 1Elzbieta (Ela) Bakbwska.应用ICP-MS技术和EPA200.8标准方法分析饮用水和污水样品[J]环境化学,2001(06).
  • 2海水水质标准[J]海洋通报,1992(03).
  • 3GB 3097-1997.海水水质标准[S],1997.
  • 4GB 17378.4-1998.海洋监测规范 第4部分;海水分析[S],1998.

共引文献13

同被引文献21

引证文献3

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部