期刊文献+

受限空间内细水雾抑制熄灭火焰过程中一氧化碳的生成率 被引量:1

Carbon Monoxide Production Rate During Fire Suppression with Water Mist in Confined Space
下载PDF
导出
摘要 细水雾抑制熄灭火焰过程中一氧化碳的浓度是评价细水雾灭火系统安全可靠性的一个重要参数.本文通过受限空间内细水雾抑制熄灭障碍火的模拟实验研究,发现细水雾抑制熄灭火焰过程中一氧化碳生成率存在两种控制模式,即燃料控制模式和细水雾流量控制模式.实验结果表明,在燃料控制模式下,一氧化碳生成率随着燃料流量的增大而增大;在细水雾控制模式下,一氧化碳生成率随着细水雾流量的增大而增大.为了获得两种控制模式的临界转变条件,对燃料控制模式和细水雾控制模式的临界工况进行水蒸气含量分析.通过理论分析,得到一氧化碳生成率控制模式转变的水蒸气含量临界范围与Suh and Atryeya理论基本一致,即空气中水蒸气质量分数达到25%~65.5%时,水蒸气对火焰的作用从化学作用转为物理作用,一氧化碳生成率控制模式开始转变. The concentration of carbon monoxide during fire suppression with water mist is one of the important parameters for safety evaluation of water mist system. Based on the experimental results of fire suppression with water mist in confined space, it is found that the carbon monoxide production rate during fire suppression is controlled in two modes. One is fuel controlled mode, and the other is water mist flux controlled mode. In the fuel controlled mode, the carbon monoxide production rate increases with the increase of fuel flux. In the water mist flux controlled mode, the carbon monoxide production rate increases with the increase of water mist flux. In order to classify the critical condition for transformation between these two modes, the concentration of water vapor in confined space is analyzed. The results show that the critical concentration of water vapor for the mode transformation is 25%--65.5%, which is consistent with Sub and Atryeya's conclusion.
出处 《燃烧科学与技术》 EI CAS CSCD 北大核心 2012年第2期175-180,共6页 Journal of Combustion Science and Technology
基金 国家重点基础研究发展计划(973计划)资助项目(2012CB719704) 国家自然科学基金资助项目(50774072) 中央高校基本科研业务费专项资金青年创新基金资助项目(WK2320000002)
关键词 细水雾 灭火 一氧化碳 生成率 受限空间 water mist fire suppression carbon monoxide production rate confined space
  • 相关文献

参考文献2

二级参考文献21

  • 1刘朝,贾彩清,张华玲,胡忠日.单室火灾水喷淋灭火的数值研究(英文)[J].燃烧科学与技术,2004,10(4):308-313. 被引量:7
  • 2王蔚,张和平,杨昀,徐亮.全尺寸多功能热释放速率实验台的设计[J].消防科学与技术,2004,23(6):521-524. 被引量:7
  • 3梁清水,梁清泉,徐文毅.细水雾特性及其灭火机理分析[J].消防科学与技术,2005,24(4):447-451. 被引量:18
  • 4Voelkert C. The New Class K [ J]. NFPA Journal, 1999(7/8) :718.
  • 5Edwards N. A new class of fire [ J]. Fire Prevention, 1998,310:8-14.
  • 6Grant G, Brenton J, Drysdale D. Fire suppression by water sprays [J]. Progress in Energy and Combustion Science,2000, 26:79-130.
  • 7Kim A, Mawhinney J, Su J. Water mist system can replace halon for use on electrical equipment[ J]. Canadian Consulting Engineer, 1996, 5:30-35.
  • 8Suh J, Atreya A. The Effect of Water Vapor on Counter Flow Diffusion Flames [ C ]//Proceedings of Mternational Conference on Fire Research and Engineering. The University of michign, 1995 : 103-108.
  • 9Koseki H, Natsume Y, Iwata Y. Combustion of high flash point materials[ C ]//Proceedings of 7th International Fire and Materials Conference. San Francisco,2001:339-349.
  • 10Council of Canadian Fire Marshals and Fire Commissioners.Fire Losses in Canada[ R]. Canda,2000.

共引文献13

同被引文献20

  • 1杨立中,武来喜,冯文兴.火灾烟气危害性气体在狭长通道内水平方向迁移的模拟实验研究[J].工程热物理学报,2007,28(z2):177-180. 被引量:5
  • 2刘璐.水喷淋对火灾烟气蔓延的数值模拟分析[J].安防科技,2010(1):48-50. 被引量:3
  • 3史聪灵,钟茂华,刘铁民,霍然.喷水排烟作用下孤岛火灾行为及烟气运动实验[J].燃烧科学与技术,2006,12(6):519-528. 被引量:6
  • 4游宇航,李元洲,王浩波,霍然.机械排烟控制小室火灾烟气的实验研究[J].燃烧科学与技术,2007,13(3):259-264. 被引量:12
  • 5Zhang X G,Guo Y C,Chan C K. Numerical simulations on fire spread and smoke movement in an underground car park[J].Building and Environment,2007.3466-3475.
  • 6Ji J,Zhong W,Li K Y. A simplified calculation method on maximum smoke temperature under the ceiling in subway station fires[J].Tunnelling and Underground Space Technology,2011.490-496.
  • 7中华人民共和国公安部.建筑设计防火规范[S]北京:中国计划出版社,2012.
  • 8Gao Ran,Li Angui,Hao Xinpeng. Fire-induced smoke control via hybrid ventilation in a huge transit terminal subway station[J].Energy and Buildings,2012.280-289.
  • 9Felis F,Pavageau M,Elicer-Cortes J C. Simultaneous measurements of temperature and velocity fluctuations in a double stream-twin jet air curtain for heat confinement in case of tunnel fire[J].International Journal of Heat and Mass Transfer,2010.1191-1196.
  • 10Pan Liwei;Lo S M;Liao Guangxuan.Experimental study of smoke control in subway station for tunnel area fire by water mist system[A]广州,2011335-342.

引证文献1

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;