期刊文献+

A Novel Grid Synchronization Control of Doubly-fed Induction Generator

A Novel Grid Synchronization Control of Doubly-fed Induction Generator
下载PDF
导出
摘要 The dynamic performance of doubly-fed induction generator(DFIG) before and after connection is analyzed based on corresponding mathematical models and transfer functions in decoupled vector control.The parameter tuning methods of rotor current regulator before and after connection are given.To reach same dynamic performance the parameters should take different values and be switched before and after connection.However on one hand the closing moment of stator contactor is difficult to get as the feedback signal is usually twenty millisecond delay or so.The delay in parameter switching will affect rotor current and torque dynamics during the delayed period after connection. On the other hand parameter switching is troublesome.Hence a synchronization control strategy without parameter switching is proposed and analyzed in detail,which has linear rising exciting current to avoid current overshooting. The dynamic performance of the proposed strategy is analyzed in frequency domain and implemented on a DFIG experimental platform subsequently.The proposed synchronization strategy is validated by experimental results. The dynamic performance of doubly-fed induction generator (DFIG) before and after connection is analyzed based on corresponding mathematical models and transfer functions in decoupled vector control.The parameter tuning methods of rotor current regulator before and after connection are given.To reach same dynamic performance the parameters should take different values and be switched before and after connection.However on one hand the closing moment of stator contactor is difficult to get as the feedback signal is usually twenty millisecond delay or so.The delay in parameter switching will affect rotor current and torque dynamics during the delayed period after connection. On the other hand parameter switching is troublesome.Hence a synchronization control strategy without parameter switching is proposed and analyzed in detail, which has linear rising exciting current to avoid current overshooting. The dynamic performance of the proposed strategy is analyzed in frequency domain and implemented on a DFIG experimental platform subsequently.The proposed synchronization strategy is validated by experimental results.
出处 《电力电子技术》 CSCD 北大核心 2012年第4期38-42,共5页 Power Electronics
关键词 摘要 编辑部 编辑工作 读者 wind power generation system doubly-fed induction generator synchronization control scheme
  • 相关文献

参考文献3

二级参考文献25

共引文献83

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部