摘要 目的:探讨小儿胸部应用DR摄影的优势。方法:随机选取50例5岁以下婴幼儿及50例5岁以上儿童胸片,分别其在拍摄中出现的问题总结分析和综合评价。结果:5岁以下50例婴幼儿胸部图像资料统计,体位不佳的7例,肩胛骨遮挡的10例,呼气相的6例,照射野范围大的2例,剂量偏低或偏高的4例。5岁以上50例儿童胸片统计。结果:体位不正的7例,肩胛骨遮挡的12例,呼气的3例,照射野范围大的7例,剂量偏低的3例。结论:应用DR系统投照小儿胸部,有效的降低对小儿辐射剂量,为临床诊断提供良好的影像照片。 objective: to explore the application of pediatric chest DR photography advantage. Methods: 50 cases randomly se- lected five years old the following infant and 50 cases for children were taken in the chest x - rays, the problems in analysis and com- prehensive evaluation. Results: 5 years old the following 50 cases chest image statistics, the infant poor posture of 7 cases, Withers keep out of 10 patients in 6 cases of breath, radiation fields of large range in 2 cases, high or low doses of 4 cases. 5 years above 50 ca- ses of children chest radiograph statistical results: position error in 7 cases, Withers keep out of 12 patients, and exhale in 3, illumi- nate the wild range of 7 cases, 3 cases of low dose. Conclusion: using DR system according to children for chest, effectively reduce the radiation dose for children, provide good for clinical diagnosis of image photos.
出处 《中国民族民间医药》 2012年第8期80-81,共2页 Chinese Journal of Ethnomedicine and Ethnopharmacy
关键词 X线 数字化 小儿 摄影 X - ray Digitization Children photograph
  • 相关文献

参考文献4

二级参考文献11

  • 1郭良栋,徐茂星,周恒根,刘元山,魏贤英.多功能直接数字化X线摄影系统的临床应用[J].实用放射学杂志,2006,22(3):358-359. 被引量:29
  • 2朱宏.CCD探测器与平板探测器的比较[J].医疗设备信息,2006,21(6):47-48. 被引量:12
  • 3Stephan M,Petra Damoser R H,Christoph E,et al.Chest Radiography with a Digital Flat-panel Detector:Experimental Receiver Operating Characteristic Analysis[J].Radiology,2005,234(3):776-784.
  • 4Shingo K,Katsumi N,Koji K.Improved Detection of Bones by Using a Temporal Subtraction Technique[J].Radiology,2002,224(1):145-451.
  • 5Harrell G,Chotas M S,Carl E,et al.Digital Abdomen Radiography with a Solid-state Flat-panel X-ray Detector:Contrast-Detail Evaluation with Processed Images Printed on Film Hard Copy[J].Radiology,2001,218(3):679-680.
  • 6Var J U,Pieper J,Renner V B,et al.Assessment of Hand Osteoarthritis:Correlation between Thermographic and Radiographic Methods[J].Rheumatology,2004,43(7):915-919.
  • 7Karl L,Kathrin A,Dag W,et al.Lumbar Spine Radiography:Digital Flat-panel Detector Versus Screen-Film and Storage-Phosphor Systems in Monkeys as a Pediatric Model[J].Radiology,2003,229(1):140-144.
  • 8《中华放射学杂志》编委会.全国放射科QA,QC学术研讨会记要,1993.
  • 9Chotas HG;Floyd CE;Ravin CE.Technical evalution of a digital chest radiography system that uses a selenium detector[J],1995.
  • 10余厚军.X线数字摄影(成像)技术原理与应用之一——间接数字化摄影[J].实用放射学杂志,2002,18(7):620-622. 被引量:60

共引文献6

同被引文献15

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部