摘要 循环水泵是火力发电厂的主要耗能设备,冷端优化是发电企业节能工作的一项重要内容。在循环水系统设计和循环水泵选型阶段,采用不同容量循环水泵进行优化配置,可以获得更加灵活的循环水流量组合以适应机组需要的冷却水量。通过不同容量循环水泵配置方案和目前循环水泵主要节能方法之间的比较,说明所选方案能够实现循环水泵的节能调节。若在2×1000MW机组中应用该配置方案,节能效果尤为显著。 Circulating water pump(CWP) is the main power consumption equipment and the cold end optimization is one of the important energy-saving items in fossil fuel power plants.The optimized allocation of CWP with unequal capacity in design stage can obtain a more flexible flow combination in order to meet the required cooling water of unit.By comparing the present energy-saving methods of CWP with the selection of CWP with unequal capacity,the scheme presented in this paper can achieve the energy-saving regulation of CWP,which will bring about a striking energy-saving effect by applying to 2×1 000 MW units.
出处 《电力建设》 2012年第4期76-79,共4页 Electric Power Construction
关键词 循环水泵 容量配置 节能 选型设计 circulating water pump(CWP) capacity allocation energy-saving selection design
  • 相关文献

参考文献4

二级参考文献9

  • 1温嘉斌,沈稼丰,周美兰.电厂用高压大型异步电机变频调速经济效益和技术问题分析[J].哈尔滨电工学院学报,1995,18(3):286-290. 被引量:3
  • 2王利国,吴小洪,齐延韦,赵伟,任斌.一种实现火电厂循环水泵变频调速的方法[J].变频器世界,2005(8):62-64. 被引量:3
  • 3ASME. PTC12. 2--1998 Performance test code on steam surface condensers[S]. New York: The American Society of Mechanical Engineers, 1998.
  • 4ASME. PTC6-2004 Steam turbines performance test codes [S]. New York: The American Society of Mechanical Engineers, 2005.
  • 5国际公式化委员会.水和水蒸汽性质参数IFC公式[M].北京:水利电力出版社,1967.
  • 6刘向民,王兴平.上海吴泾第二发电有限责任公司2×600MW机组循环水和真空系统优化试验报告[z].上海发电设备成套设计研究院,2007.
  • 7吴民强.泵与风机节能技术[M].北京:中国电力出版社,1998..
  • 8孙宝成,金哲.现代节电技术与节电工程[M].北京:中国水利水电出版社,2005.
  • 9程金.火电厂循环水泵变频驱动控制系统.变频器世界,2003,(6).