摘要
文中介绍了柜式气体绝缘金属封闭开关设备(C-GIS)在设计开发中的温升问题,其中介绍了温升产生的原因,危害,及解决的相关措施,设备温度升高包括导体发热,感应发热,提高设备绝缘件的耐热性能。提高设备的散热效果,从热传导、对流传导、热辐射几方面介绍了热了解决气箱的散热问题。
This paper introduces the cabinet gas insulated metal enclosed switchgear(C-GIS) in the design and development of temperature rising,which presents the temperature rise causes,harm,and solve the relevant measures,equipment temperature comprises a conductor heating,induction heating,improve equipment insulation heat resistance.Improve equipment heat dissipation effect,the heat conduction,convection conduction,heat radiation is discussed to solve the gas tank of heat radiating problem.
出处
《装备制造技术》
2012年第3期206-207,共2页
Equipment Manufacturing Technology
关键词
发热抑制
耐热技术
散热措施
fever suppression
heat
heat dissipation measures