以某工程的地源热泵空调及生活热水系统调试的有关监控要求为例,从生活热水系统运行要求、系统调试监控要点及其调试结果分析等方面介绍了调试监控的方法,即为确保该系统满足设计要求的节能减排目标,应先进行分区、分子系统调试,合格后再联合调试,实时总结调试期间出现的不足并及时修正,为类似工程的调试监控工作提供借鉴。
Based on related monitoring requirements for debugging system and domestic hot-water system of a project, following aspects, including operation requirement of the debugging of geothermal heat monitoring method pump air conditioning is introduced on the domestic hot-water system, key points for monitoring onsystem debugging and analysis on debugging result, etc. To ensure the energy conservation and emission reduction required in design can be satisfied, the system shall be debugged in subzones and subsystems before joint debugging. Problems detected in debugging shall be summarized and corrected timely, so as to provide references for debugging monitoring of similar projects.
出处
《建筑技术》
2012年第4期310-312,共3页
Architecture Technology
关键词
地源热泵系统
调试
热媒
空调
生活热水
geothermal heat pump system
debugging
heating medium
air conditioning
domestic hot water