摘要
介绍了2MV激光触发多级气体开关在强光一号加速器上的实验研究工作。给出了实验方案,激光触发信号采用轴向引入的方法,激光光路穿过二极管,沿水线轴向引入开关;分析了开关自击穿实验和触发实验的实验结果,总结了实验中出现的问题并对其原因进行了分析,提出了改进措施。结果表明,开关最大工作电压2MV,最大电流大于600kA,当欠压比88.3%时,激光触发开关的平均延时34.2ns,抖动小于3.86ns。
The paper presents the experimental investigation of laser triggered gas switch on Qiangguang-Ⅰ accelerator.In the experiments,the laser was transmitted along the axes of the water line through the diode.The results of self-breakdown experiments and trigger experiments are presented and analyzed.At the undervoltage ratio of 88.3%,the average delay of the laser triggered gas switch is 34.2 ns,and the time jitter is less than 3.86 ns,when the maximal operating voltage is 2 MV and the maximal current is over 600 kA.The problems occurring during experiments are summarized and analyzed,and corresponding improvement measures are proposed.
出处
《强激光与粒子束》
EI
CAS
CSCD
北大核心
2012年第3期549-553,共5页
High Power Laser and Particle Beams
关键词
激光触发
气体开关
延时
抖动
自击穿
laser trigger
gas switch
delay
jitter
self-breakdown