期刊文献+

反应堆主泵压水室出口收缩角对水力性能的影响 被引量:10

Effect of Pumping Chamber Outlet Contraction Angle on Hydraulic Performance of Main Nuclear Reactor Pump
下载PDF
导出
摘要 针对国内某百万千瓦核反应堆主泵的水力性能要求,完成主泵叶轮和导叶的设计;为研究出口收缩角对水力性能的影响,设计了13种压水室出口收缩角,采用三维软件Pro/E完成了三维造型;利用计算流体力学(CFD)软件Fluent进行定常与非定常三维数值模拟,得到内部流场特性及计算点的压力脉动情况,并对其进行分析。结果表明:收缩角对压水室与出口交接处的前后区域影响显著,收缩角在12°~16°范围内,主泵效率均在70%以上,=15°时效率达最大值74.2%;在=15°且其他结构参数不变的情况下,随着流量的降低,主泵叶轮进口前和导叶出口处回流区域逐渐扩大;随着流量的增加,叶轮进口前回流区域逐渐向叶轮进口偏移;回流是引起压水室与出口交接处压力脉动的主要原因;偏离工况越大,压水室出口处的压力脉动波动越严重。 An RCP(reactor coolant pump) impeller and diffuser are designed to meet the hydraulic performance needs of the nuclear reactor coolant pump in a domestic 1000MW nuclear power plant.In order to study the effect of the pumping chamber outlet contraction angle,13 kinds of are designed and Pro/E is utilized for three-dimensional design,and CFD code Fluent is utilized for numerical simulation.Finally,the internal velocity vector and streamline of the RCP are obtained.It is revealed that the contraction angle has a significant effect on the connection area between pumping chamber and outlet.As is between 12° and 16°,and the efficiency of the RCP is above 70%.When is 15°,the efficiency reaches to the maximum 74.2%.When is 15° and other parameters unchanged,the reverse flow region of the impeller inlet and diffuser outlet becomes larger with the decrease of the flow rates.When the flow increases,the reverse region approaches closer to the impeller inlet.Reverse flow is the main cause of the pressure fluctuation of the connection area between pumping chamber and outlet,and the farther away the design point,the more serious the pressure fluctuation.
机构地区 江苏大学
出处 《核动力工程》 EI CAS CSCD 北大核心 2012年第2期97-103,共7页 Nuclear Power Engineering
基金 国家杰出青年基金(50825902) 江苏省自然科学基金(BK2011504) 江苏高校优势学科建设工程资助项目苏政办发(2010)118号
关键词 主泵 压水室出口收缩角 数值模拟 回流 压力脉动 Reactor Coolant Pump(RCP) Chamber outlet contraction angle Numerical simulation Reverse flow Pressure fluctuation
  • 相关文献

参考文献11

  • 1Pavlin Groudev,Antoaneta Stefanova.Validation ofRELAP5/MOD3.2 Model on Trip Off One Main CoolantPump for VVER 440/V230[J].Nuclear Engineering andDesign,2006,236(12):1275-1281.
  • 2In Soo Koo,Whan Woo Kim.The Development ofReactor Coolant Pump Vibration Monitoring and ADiagnostic System in the Nuclear Power Plant[J].ISATransactions,2000,39:309-316.
  • 3Kazem Farhadi,Anis Bousbia-salah,Fransceso D Auria.A Model for the Analysis of Pump Start-Up Transients inTehran Research Reactor[J].Progress in Nuclear Energy,2007,49:499-510.
  • 4Li Ying,Zhang Jige,Wang Dezhong.Fatigue ReliabilityAnalysis of the Nuclear Coolant Circulating Pump’SImpeller[C].ASME 17th International Conference onNuclear Engineering(ICONE17),Iconne17-75438,Brussels,Belgium.2009.
  • 5Li Liang,Wang Xiaofang.Numerical Investigati-on onthe Interaction Between theVolute and Diffus-Er WithDifferent Outlet Angles in Nuclear Main Pump[C].Asia-Pacific Power and EnergyEngineering Conference(APPEEC 2010),Chengdu,China.2010.
  • 6朱荣生,欧鸣雄.低比转数双吸离心泵回流问题的CFD研究[J].农业机械学报,2009,40(4):82-85. 被引量:12
  • 7陈向阳,袁丹青,杨敏官,袁寿其.300MW级核电站主泵压力脉动研究[J].核动力工程,2010,31(3):78-82. 被引量:10
  • 8王春林,彭娜,赵佰通,司艳雷.核主泵模型泵导叶进口边相对位置对泵性能的影响[J].排灌机械,2008,26(5):38-41. 被引量:27
  • 9Sierra F Z,Mazur Z,Kubiak J,et al.Modelig of theFlow At The Last Stage Blade Tenon in A Geoth-ErmalTurbine Using Renorm Alization Group TheoryTurbulence Model[J].Applied Thermal Engineering,2000,20:81-101.
  • 10唐宏芬,张梁,吴玉林.双级轴流泵内部三维紊动流场CFD分析[J].工程热物理学报,2003,24(3):423-425. 被引量:27

二级参考文献37

共引文献76

同被引文献79

引证文献10

二级引证文献54

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史