基于四肢同步检测踝臂指数的方法和临床研究

Detection Method and Clinical Research on Ankle Brachial Index Based on Synchronous Measurements of Four Limbs
下载PDF
导出
摘要 目的利用优选法在波形特征法和幅度系数法的基础上提出1种同步采集四肢脉搏波信号和袖套压力波信号无创检测踝臂指数的新方法。方法计算出相邻脉搏波的幅度差值和它们的相对比值,并利用优选法在一定范围内进行突变点的判断。结果该方法能够解决将收缩压以前的点和平均压附近的点误判为突变点的问题,大量的病例分析和临床测试证实了该算法的有效性和可靠性。结论踝臂指数是动脉硬化的一个简便可靠的预测因素,它与传统的动脉硬化危险因素如年龄、血压等有相关性。 Objective To find a new algorithm for detecting ankle brachial index(ABI) non-invasively by synchronous acquisition of four limbs pulse wave signals and cuff pressure wave signals basing on waveform characteristic method and amplitude coefficient method with priority rule.Methods The turning point was judged in certain range by calculating the difference of adjoining pulse waves and their relative ratio under priority rules.Results The method provided a solution to misjudgment problem of the turning point before systolic blood pressure and around average pressure.Many cases analyses and lots of clinical tests proved the algorithm effective and reliable.Conclusion ABI is a handy and dependable predictor of atherosclerosis,it is associated with conventional risk factors such as age,blood pressure,etc.
出处 《航天医学与医学工程》 CAS CSCD 北大核心 2012年第2期112-115,共4页 Space Medicine & Medical Engineering
基金 国家自然科学基金项目资助(50876120) 重庆市自然科学基金项目资助(CSTC2006BB2408)
关键词 踝臂指数 外周动脉疾病 动脉硬化 优选法 ankle brachial index peripheral arterial disease arteriosclerosis priority rules
  • 相关文献

参考文献10

  • 1李燕,王继光.踝部血压测量及踝臂血压指数[J].中华高血压杂志,2008,16(7):665-668. 被引量:12
  • 2Suominen V,Rantanen T,Venermo M. Prevalence and risk factors of PAD among patients with elevated ABI[J].European Journal of Vascular and Endovascular Surgery,2008,(06):709-714.doi:10.1016/j.ejvs.2008.01.013.
  • 3Wikstrom J,Hansen t,Johansson L. Ankle brachial index 《 0.9 underestimates the prevalence of peripheral artery occlucive diseases assessed with whole-body magnetic response angiography in the elderly[J].Acta Radiologica,2008,(02):143-149.
  • 4Fleck CA. Measuring ankle brachial pressure index[J].Advances in Skin & Wound Care,2007,(12):646-650.doi:10.1097/01.ASW.0000284962.39369.27.
  • 5MacDonald E,Froggatt P,Lawrence G. Are automated blood pressure monitors accurate enough to calculate the ankle brachial pressure index[J].Journal of Clinical Monitoring and Computing,2008,(05):381-384.doi:10.1007/s10877-008-9146-8.
  • 6李觉,李宪凯,罗盈怡,邢燕,郑黎强,刘浩,余金明,胡大一.女性多重动脉硬化患者踝臂指数与全因死亡和心血管疾病死亡关系的群组研究[J].中国实用内科杂志,2007,27(9):662-665. 被引量:8
  • 7Resnick HE,Lindsay RS,McDermott MM. Relationship of high and low ankle brachial index to all-cause and cardiovascular disease mortality:the strong heart study[J].Circulation,2004.733-739.doi:10.1161/01.CIR.0000112642.63927.54.
  • 8Mukherjee D,Cho L. Peripheral arterial disease:considerations in risks,diagnosis,and treatment[J].Journal of the National Medical Association,2009,(10):999-1008.
  • 9马改翠,高妹花,刘翠霞.在踝部测量下肢血压的方法[J].护理实践与研究,2008,5(19):9-9. 被引量:6
  • 10王吉宏,赵志萍,王丁香.听诊法血压测量的方法学和影响因素[J].中华高血压杂志,2008,16(10):955-958. 被引量:9

二级参考文献32

  • 1李宪凯,李觉,余金明,仝其广,郑黎强,罗盈怡,布艾加尔.哈斯木,田巨龙,张汝林,崔思芳,胡大一.四川攀枝花地区部分城镇与乡村居民血脂水平及踝臂指数的比较[J].中国实用内科杂志:临床前沿版,2006,26(8):1255-1257. 被引量:3
  • 2李觉.中国下肢动脉疾病研究系列报道——高危人群下肢动脉疾病的全因及心血管病病死率和危险比[J].中国实用内科杂志,2006,26(11):1685-1687. 被引量:5
  • 3[1]Winsor T.Influence of arterial disease on the systolic blood pressure gradients of the extremity[J].Am J Med Sci,1950,220:117-126.
  • 4[2]Yao JST,Hobbs JT,Irvine WT.Ankle systolic pressure measurements in arterial diseases affecting the lower extremities[J].Br J Surg,1969,56:676-679.
  • 5[3]Klein S,Hage JJ.Measurement,calculation,and normal range of the ankle-arm index:a bibliometric analysis and recommendation for standardization[J].Ann Vasc Surg,2006,20:282-292.
  • 6[4]Hirsch AT,Haskal ZJ,Hertzer NR,et al.ACC/AHA 2005 Practice Guidelines for the management of patients with peripheral arterial disease (lower extremity,renal,mesenteric,and abdominal aortic)[J].Circulation,2006,113:e463-654.
  • 7[5]Matzke S,Franchena M,Alback A,et al.Ankle-brachial index measurements in critical leg ischaemia -the influence of experience on reproducibility[J].Scand J Surg,2003,92:144-147.
  • 8[6]Kaiser V,Kester A,Stoffers H,et al.The influence of experience on the reproducibility of the ankle-brachial systolic pressure ratio in peripheral arterial occlusive disease[J].Eur J Vasc Endovasc Surg,1999,18:25-29.
  • 9[7]Adiseshiah M,Cross FW,Belsham PA.Ankle blood pressure measured by automatic oscillotonometry:a comparison with Doppler pressure measurements[J].Ann R Coll Surg Engl,1987,69:271-273.
  • 10[8]Ramanathan A,Conaghan PJ,Jenkinson AD,et al.Comparison of ankle-brachial pressure index measurements using an automated oscillometric device with the standard Doppler ultrasound technique[J].ANZ J Surg,2003,73:105-108.

共引文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部