摘要
采用顶空气相色谱法,测定延胡索酸泰妙菌素原料药中甲醇和乙酸乙酯有机溶剂的残留量。结果表明,甲醇和乙酸乙酯在设定范围内有较好的线性,其r值分别为0.9999和0.9998,平均回收率分别为100.1%和99.6%,相对标准偏差分别为1.12%、1.07%。该方法灵敏准确,重现性好,适用于延胡索酸泰妙菌素原料药中有机溶剂残留量的测定。
Using headspace gas chromatography.Determination of tiamulin fumarate raw materials of methanol and ethyl acetate in organic solvent residue.The results show that.Methanol and ethyl acetate in set range there is a good linear.The R values were 0.9999 and 0.9998.The average recovery rate was 100.1 % and 99.6 % respectively.The relative standard deviations were 1.12 %,1.07 %.The method is sensitive and accurate.Reproducible.Suitable for tiamulin fumarate raw materials Determination of residual organic solvents in.
出处
《广东化工》
CAS
2012年第4期163-163,195,共2页
Guangdong Chemical Industry