期刊文献+

煤气湿式电除尘器洗涤水循环利用的研究

STUDY ON RECYCLING USE OF GAS WASHING WASTEWATER FROM WET ELECTROSTATIC PRECIPITATOR
原文传递
导出
摘要 采用化学混凝、絮凝以及离子交换软化的方法处理钢厂煤气湿式电除尘器(ESP)洗涤废水,设计出小型、高效的废水处理及回用系统。以废水的SS、总硬度、总碱度为主要因子,在浓度分别为350,365,315 mg/L的条件下,经过两个主要单元的处理后,浓度可达7,75,70 mg/L,达到回用标准,降低了运行成本,环境效益显著。 Chemical coagulation,flocculation and ion exchange softening were used to deal with gas washing wastewater from wet electrostatic precipitator.A small and efficient wastewater treating and reusing systems were designed.SS,total hardness and total alkalinity in the wastewater were used as the main factors,when the inlet concentration was 350,365 and 315 mg/L,the outlet concentration could reach 7,75 and 70 mg/L after two main units treatment.The technology can meet the recycle standard,its operation cost is low and environmental efficiency is good.
出处 《环境工程》 CAS CSCD 北大核心 2012年第2期37-40,43,共5页 Environmental Engineering
基金 河北省重大技术创新项目"大型燃气-蒸汽联合循环发电机组煤气净化关键技术"(10273920Z)
关键词 废水处理及回用 煤气洗涤水 化学混凝 絮凝 离子交换软化 wastewater treatment and reuse gas washing wastewater chemical coagulation flocculation ion exchange softening
  • 相关文献

参考文献3

二级参考文献15

共引文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题