摘要 发电机冷却水控制 pH、电导率和水中铜离子含量 ,是为了保证发电机有足够的电气绝缘性能和防止对空芯铜导线产生侵蚀性。发电机冷却水水质标准有SD1 63— 1 985、GB1 2 1 45— 1 989、GB760 4— 1 986,其控制指标各异。阐述了三个标准中电导率、pH不同的原因 ,根据理论计算和实际分析 ,按SD1 63— 1 985控制电导率在 5 0 μS/cm以内 ,既能保证发电机的电气绝缘性能 ,又可通过提高 pH值或向冷却水中加入缓蚀剂 ,达到防腐目的。因此 ,建议采用SD1 63— 1 985作为发电机冷却水水质标准。 Generator cooling water controls pH, conductance rate and the content of copper ion in water. It is to guarantee that the generator has enough electric insulation performance and to protect the core copper wire from corrosion. The three kinds of water standards of generator cooling water are SD163-1985, GB12145-1989 and GB7064-1986. Their targets are different. The report expounds the reason of different conductance rates and pH in the three standards. According to theoretical calculation with practice, When SD163-1985 controls the conductance rate, it's lower than 5 μS/cm, and it can guarantee electric insulation performance of the generator, and it is anticorrosive with the raising of pH or pouring scale inhibitor into cooling water. So, the author suggests using SD163-1985 as water standard of generator cooling water.
作者 刘瑛
出处 《工业水处理》 CAS CSCD 2000年第6期31-33,共3页 Industrial Water Treatment
关键词 发电机 冷却水 腐蚀 水质标准 冷却 generator cooling water copper corrosion electric insulation performance