期刊文献+

Energy efficiency performance of multi-energy district heating and hot water supply system 被引量:2

Energy efficiency performance of multi-energy district heating and hot water supply system
下载PDF
导出
摘要 A district heating and hot water supply system is presented which synthetically utilizes geothermal energy,solar thermal energy and natural gas thermal energy.The multi-energy utilization system has been set at the new campus of Tianjin Polytechnic University(TPU),A couple of deep geothermal wells which are 2 300 m in depth were dug,Deep geothermal energy cascade utilization is achieved by two stages of plate heat exchangers(PHE) and two stages of water source heat pumps(WSHP).Shallow geothermal energy is used in assistant heating by two ground coupled heat pumps(GCHPs) with 580 vertical ground wells which are 120 m in depth.Solar thermal energy collected by vacuum tube arrays(VTAs) and geothermal energy are complementarily utilized to make domestic hot water.Superfluous solar energy can be stored in shallow soil for the GCHP utilization.The system can use fossil fuel thermal energy by two natural gas boilers(NGB) to assist in heating and making hot water.The heating energy efficiency was measured in the winter of 2010-2011.The coefficients of performance(COP) under different heating conditions are discussed.The performance of hot water production is tested in a local typical winter day and the solar thermal energy utilization factor is presented.The rusults show that the average system COP is 5.75 or 4.96 under different working conditions,and the typical solar energy utilization factor is 0.324. A district heating and hot water supply system is presented which synthetically utilizes geothermal energy, solar thermal energy and natural gas thermal energy. The multi-energy utilization system has been set at the new campus of Tianjin Polytechnic University (TPU). A couple of deep geothermal wells which are 2 300 m in depth were dug. Deep geothermal energy cascade utilization is achieved by two stages of plate heat exchangers (PHE) and two stages of water source heat pumps (WSHP). Shallow geothermal energy is used in assistant heating by two ground coupled heat pumps (GCHPs) with 580 vertical ground wells which are 120 m in depth, Solar thermal energy collected by vacuum tube arrays (VTAs) and geothermal energy are complementarily utilized to make domestic hot water. Superfluous solar energy can be stored in shallow soil for the GCHP utilization. The system can use fossil fuel thermal energy by two natural gas boilers (NGB) to assist in heating and making hot water. The heating energy efficiency was measured in the winter of 2010-2011. The coefficients of performance (COP) under different heating conditions are discussed. The performance of hot water production is tested in a local typical winter day and the solar thermal energy utilization factor is presented. The rusults show that the average system COP is 5.75 or 4.96 under different working conditions, and the typical solar energy utilization factor is 0.324.
出处 《Journal of Central South University》 SCIE EI CAS 2012年第5期1377-1382,共6页 中南大学学报(英文版)
基金 Project(2010DFA72740-06) supported by International Science & Technology Cooperation Program of China
关键词 热水供应系统 能源效益 集中供热 太阳能热利用 板式换热器 天然气锅炉 冬季供暖 太阳能利用率 geothermal energy solar thermal energy district heating hot water supply
  • 相关文献

参考文献16

  • 1Building Energy Conservation Res-arch Center of Tsinghua University.2011 Annual report on China building energy efficiency(in Chinese)[M]北京:中国建筑工业出版社,20112-3.
  • 2HEPBASLI A,CANAKCI C. Geothermal district heating applications in Turkey:A case study of lzmir-Balcova[J].Energy Conversion and Management,2003.1285-1301.
  • 3ERDOGMUS B,TOKSOY M,OZERDEM B,AKSOY N. Economic assessment of geothermal district heating systems:a case study of Balcova-Narlidere,turkey[J].Energy and Buildings,2006.1053-1059.
  • 4OKTAY Z,ASLAN A. Geothermal district heating in Turkey:The Gonen casc study[J].Geothermics,2007.167-182.
  • 5OZGENER L,HEPBASLI A,DINCER I. A key review on performance improvement aspects of geothermal district heating systems and applications[J].Renewable & Sustainable Energy Reviews,2007.1675-1697.
  • 6YILDIRIM N,TOKSOY M,GOKCEN G. Piping network design of geothermal district heating systems:Case study of a university campus[J].Energy,2010.3256-3262.
  • 7KECEBAS A. Performance and thermo-economic assessments of geothermal district heating system:A case study in Afyon,Turkey[J].Renewable Energy,2011.77-83.
  • 8OZGENER L,HEPBASLI A,DINCER I. Energy and exergy analysis of geothermal district heating systems:An application[J].Building and Environment,2005.1309-1322.
  • 9OZGENER L,HEPBASLI A,DINCER I. Energy and exergy analysis of Gonen geothermal district heating system,Turkey[J].Geothermics,2005.632-645.
  • 10OZGENER L,HEPBASLI A,DINCER I. Performance investigation of two geothermal district heating systems for building applications:Energy analysis[J].Energy and Buildings,2006.286-292.

同被引文献9