期刊文献+

Effect of artificial aeration on the performance of vertical-flow constructed wetland treating heavily polluted river water 被引量:38

Effect of artificial aeration on the performance of vertical-flow constructed wetland treating heavily polluted river water
原文传递
导出
摘要 Three lab-scale vertical-flow constructed wetlands (VFCWs), including the non-aerated (NA), intermittently aerated (IA) and continuously aerated (CA) ones, were operated at different hydraulic loading rates (HLRs) to evaluate the effect of artificial aeration on the treatment efficiency of heavily polluted river water. Results indicated that artificial aeration increased the dissolved oxygen (DO) concentrations in IA and CA, which significantly favored the removal of organic matter and NH4+-N. The DO grads caused by intermittent aeration formed aerobic and anoxic regions in IA and thus promoted the removal of total nitrogen (TN). Although the removal efficiencies of CODEr, NH4+-N and TN in the three VFCWs all decreased with an increase in HLR, artificial aeration enhanced the reactor resistance to the fluctuation of pollutant loadings. The maximal removal efficiencies of CODEr, NH4+-N and total phosphorus (TP) (i.e., 81%, 87% and 37%, respectively) were observed in CA at 19 cm/day HLR, while the maximal TN removal (i.e., 57%) was achieved in IA. Although the improvement of artificial aeration on TP removal was limited, this study has demonstrated the feasibility of applying artificial aeration to VFCWs treating polluted river water, particularly at a high HLR. Three lab-scale vertical-flow constructed wetlands (VFCWs), including the non-aerated (NA), intermittently aerated (IA) and continuously aerated (CA) ones, were operated at different hydraulic loading rates (HLRs) to evaluate the effect of artificial aeration on the treatment efficiency of heavily polluted river water. Results indicated that artificial aeration increased the dissolved oxygen (DO) concentrations in IA and CA, which significantly favored the removal of organic matter and NH4+-N. The DO grads caused by intermittent aeration formed aerobic and anoxic regions in IA and thus promoted the removal of total nitrogen (TN). Although the removal efficiencies of CODEr, NH4+-N and TN in the three VFCWs all decreased with an increase in HLR, artificial aeration enhanced the reactor resistance to the fluctuation of pollutant loadings. The maximal removal efficiencies of CODEr, NH4+-N and total phosphorus (TP) (i.e., 81%, 87% and 37%, respectively) were observed in CA at 19 cm/day HLR, while the maximal TN removal (i.e., 57%) was achieved in IA. Although the improvement of artificial aeration on TP removal was limited, this study has demonstrated the feasibility of applying artificial aeration to VFCWs treating polluted river water, particularly at a high HLR.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2012年第4期596-601,共6页 环境科学学报(英文版)
基金 support from the Ministry of Environmental Protection (No.2008ZX07101-006-08) the Ministry of Science and Technology of China (No. 2009BAC57B02)
关键词 vertical-flow constructed wetland artificial aeration polluted fiver water hydraulic loading rate vertical-flow constructed wetland artificial aeration polluted fiver water hydraulic loading rate
  • 相关文献

参考文献30

  • 1Arias C A,Del Bubba M,Brix H,2001. Phosphorus removal bysands for use as media in subsurface flow constructed reedbeds. Water Research,35(5): 1159-1168.
  • 2Bodelier P L E,Libochant J A,Blom C W P M,LaanbroekH J,1996. Dynamics of nitrification and denitrificationin root-oxygenated sediments and adaptation of ammonia-oxidizing bacteria to low-oxygen or anoxic habitats.Applied and Environmental Microbiology,62(11): 4100-4107.
  • 3Braskerud B C,2002. Factors affecting phosphorus retention insmall constructed wetlands treating agricultural non-pointsource pollution. Ecological Engineering,19(1): 41-61.
  • 4Brix H,1997. Do macrophytes play a role in constructedtreatment wetlands? Water Science and Technology,35(5):11-17.
  • 5Bu H M,Tan X,Li S Y,Zhang Q F,2010. Temporal and spatialvariations of water quality in the Jinshui River of the SouthQinling Mts.,China. Ecotoxicology and EnvironmentalSafety,73(5): 907-913.
  • 6Calheiros C S C,Rangel A O S S,Castro P M L,2007. Construct-ed wetland systems vegetated with different plants appliedto the treatment of tannery wastewater. Water Research,41(8): 1790-1798.
  • 7De-Bashan L E,Bashan Y,2004. Recent advances in removingphosphorus from wastewater and its future use as fertilizer(1997-2003). Water Research,38(19): 4222-4246.
  • 8Fraser L H,Carty S M,Steer D,2004. A test of four plant speciesto reduce total nitrogen and total phosphorus from soilleachate in subsurface wetland microcosms. BioresourceTechnology,94(2): 185-192.
  • 9Greenway M,2005. The role of constructed wetlands in sec-ondary effluent treatment and water reuse in subtropical andarid Australia. Ecological Engineering,25(5): 501-509.
  • 10Guo L,2007. Ecology-Doing battle with the green monster ofTaihu Lake. Science,317(5842): 1166.