摘要 针对危险系数较高的油罐区防雷难题,仅依靠传统接闪杆等直击雷防护系统已无法进行有效保护,提出了一种比较经济、合理、行之有效的防雷办法。首先对油罐区的防直击雷的方式进行分析,结合现有的防雷措施以及现场情况,对传统的独立接闪杆设置方法进行改进,应用接闪杆、避雷线相互结合的方式进行油罐区的有效防雷;然后在此基础上对仪表控制系统进行科学设计,有效防护。该综合防雷技术已成功应用于工程实践。 For the lightning surge protection of oilcan farm with high risk coefficient, it is not enough for protection with traditional lightning surge protection system of lightning rod. An economic, reasonable and effective lightning surge protection method is proposed. The direct lightning surge protection mode in the oilcan farm is evaluated, combining with current lightning surge protection measures and site situation, the setting mode for the lightning surge protection rod has been modified, and the combination mode of lightning protection with rod and line is efficient to the oilcan farm. Based on this new mode, the instrument control system has been designed scientifically, and is efficient for protection. The comprehensive lightning protection technology has been successfully applied in the engineering.
作者 姚薇 李明军
出处 《石油化工自动化》 CAS 2012年第2期16-19,共4页 Automation in Petro-chemical Industry
关键词 油罐区 接闪杆避雷线结合 浪涌保护器 综合防雷技术 oilcan farm lightning rod and wire combination SPD comprehensive lightning protection technology
  • 相关文献

参考文献10

二级参考文献10

  • 1陈岩.“6.27”特大火灾事故的原因分析[J].消防科学与技术,2005,24(2):245-248. 被引量:2
  • 2GBJ65-83.工业与民用电力装置的接地设计规范[S].[S].,..
  • 3SDJ8-79.电力设备接地设计技术规程[S].[S].,..
  • 4SH3081-1997.石油化工仪表接地设计规范[S].[S].,..
  • 5SH3521-1999.石油化工仪表工程施工技术规范[S].[S].,..
  • 6GBJ93-86.工业自动化仪表工程施工及验收规范[S].[S].,..
  • 7GB50169-92.电气装置安装工程接地装置施工及验收规范[S].[S].,..
  • 8郭铁男.中国消防手册[M].上海:上海科学技术出版社,2006.
  • 9扬胜璧,许建光.化学危险品安全实用手册[M].成都:四川科学技术出版社,1987.
  • 10杨万国.接地装置及其实践[J].石油仪器,2003,17(5):56-59. 被引量:2

共引文献50

同被引文献26

引证文献5

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部