期刊文献+

电感耦合等离子体质谱法测定地质样品中铜锌铕钆铽的干扰及校正 被引量:15

Interference Correction in Determination of Cu,Zn,Eu,Gd,Tb in Geological Samples by Inductively Coupled Plasma-Mass Spectrometry
下载PDF
导出
摘要 由于电感耦合等离子体质谱(ICP-MS)分析不是在封闭的真空系统中进行,在测定过程中,气体、水和酸产生的一些离子都可能进入检测系统,产生干扰,严重影响痕量元素的准确分析。文章采用氢氟酸-硝酸封闭压力酸溶分解样品,ICP-MS法同时测定地质样品中Cu、Zn、Eu、Gd、Tb,研究了Ti、Ba、Ce、Pr、Nd对Cu、Zn、Eu、Gd、Tb的干扰情况。实验选择质量数65Cu、66Zn、153Eu、157Gd、159Tb作为测定同位素,用干扰系数脱机校正法校正分别来自Ti、Ba、Ce、Pr、Nd的氧化物重叠干扰,有效地解决了被干扰元素在测定时数值准确度低的问题。方法检出限(稀释因子1000)为:Cu 0.47μg/g、Zn 0.82μg/g、Eu 0.002μg/g、Gd 0.004μg/g、Tb 0.002μg/g,方法精密度(RSD,n=12)<5%,准确度(RE)<5%。方法用岩石、土壤、水系沉积物国家一级标准物质进行验证,测定值与标准值相符,适用于地质样品中Cu、Zn、Eu、Gd、Tb的测定。 Since Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) detection is not in a closed vacuum system,ions generated from gas,water and acid may enter the detection system in the test procedures,resulting in interference,which affects accurate analysis for trace elements.Geological samples were decomposed by pressurized acid digestion of HF-HNO3,and Cu,Zn,Eu,Gd and Tb were simultaneously determined by ICP-MS.The instrument operating parameters were optimized and the interferences from the coexisting elements of Ti,Ba,Ce,Pr,Nd for the determination of Cu,Zn,Eu,Gd,Tb were studied.The interference correction of oxide interferences for the elements Ti,Ba,Ce,Pr and Nd was performed with interference coefficients by mathematical method,which improved the accuracy for Cu,Zn,Eu,Gd,Tb determination in geological samples.Interference coefficients of Cu,Zn,Eu,Gd and Tb were calibrated by determining similar concentrations of the interference elements Ti,Ba,Ce,Pr,Nd.The detection limits(10SD) for Cu,Zn,Eu,Gd and Tb were 0.47,0.82,0.002,0.004 and 0.002 μg/g,respectively.Both the accuracy and precision of the method were validated by analyzing standard reference materials GBW 07104,GBW 07105,GBW 07123,GBW 07303,GBW 07311,GBW 07402 and GBW 07404 with RSD(n=12) less than 5.0% and RE(n=12) less than 5.0%.The results were in good agreement with the certified values of the national standard materials of rock,soil and stream sediments.The method has been successfully used in practice for Cu,Zn,Eu,Gd and Tb determination in geological samples.
出处 《岩矿测试》 CAS CSCD 北大核心 2012年第2期253-257,共5页 Rock and Mineral Analysis
基金 国家地质实验测试中心基本科研业务费项目(121235068101842) 中国地质大调查项目(1212011120272)
关键词 地质样品 电感耦合等离子体质谱法 干扰校正 geological samples Cu Zn Eu Gd Tb inductively coupled plasma-mass spectrometry interference correction
  • 相关文献

参考文献17

二级参考文献103

共引文献499

同被引文献1271

引证文献15

二级引证文献100

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部