期刊文献+

基于差分吸收光谱法的在线连续污染物监测系统

On-line pollution monitoring system based on differential optical absorption spectroscopy
下载PDF
导出
摘要 针对在固定污染源烟气排放检测中无法连续精确测量污染气体的现状,设计了一个基于差分吸收光谱法(DOAS)的在线连续监测系统。该系统采用ARM和DSP为核心,以Linux为操作系统,以MiniGUI为交互界面环境,它分为光谱数据采集模块、主控模块两部分;光谱采集模块控制光谱数据的采集过程,主控模块负责气体浓度计算和显示。研究结果表明,使用该系统,可以连续精确采集SO2与NO等气体,气体采集的稳定性和精度较高,但在高温环境测试和高浓度气体测试时误差均过高,有待进一步改进。 Aiming at the present situation that can not detect the fixed source of pollution continuously and accurately,an online continuous monitoring system based on differential optical absorption spectroscopy(DOAS) was designed.Continuously and accurately,the ARM and DSP core,the Linux operating system,and MiniGUI interface environment were used for system development.The system was consisted of spectral data acquisition module and control module.The process of spectral data acquisition was controlled by spectral acquisition and the control module was used for calculating and displaying the gas concentration.The results indicate that the online continuous monitoring system can collecte gases such as SO2 and NO and has high stability and accuracy.However,the test error is too high when testing in high temperature and high concentration,and this needs further improvement.
作者 白杨 董宝力
出处 《机电工程》 CAS 2012年第4期385-389,共5页 Journal of Mechanical & Electrical Engineering
关键词 差分吸收光谱法 CCD传感器 ARM 数字信号处理器 S3C2440 氙灯 differential optical absorption spectroscopy(DOAS) charge coupled device(CCD) ARM digital signal processing(DSP) S3C2440 xenon lamp
  • 相关文献

参考文献7

二级参考文献34

  • 1水泥工业大气污染物排放标准(GB4915—2004代替GB4915—1996)[J].中国水泥,2005(2):7-11. 被引量:2
  • 2徐祥德,周秀骥,施晓晖.城市群落大气污染源影响的空间结构及尺度特征[J].中国科学(D辑),2005,35(A01):1-19. 被引量:70
  • 31,Platt U,Perner D,Patz H,Simultaneous measurement of atmosph eric CH2O,O3 and NO2 by differential optical absorption.J Geophys Res ,1979,84(C10):6329~6335
  • 42,Hardin R W.Remote sensing keeps industry clean.Photonics Spectra,1998,4:102~ 109
  • 53,Platt U.Differential optical absorption spectroscopy (DOAS).In Sigrist M W,ed:Air monitoring by spectroscopic techniques.Chemical Analysis Series.New York:Wiley,1994,Vo1.127:27~84
  • 64,Platt U.Spectroscopic measurement of free radicals (OH,NO3) in the a tmosphere.Fresenius Z Anal Chem,1991,340:633~637
  • 75,Platt U.Measurement of atmospheric trace gases by long path differetia l UV/visible absorption spectrocopy.in Killinger D K ed:Optical and Laser Remote Sensing,New York:springer-Verlag,1983:95~105
  • 86,Brauers T.Improvement of differential optical absorption spectroscopy with a multichannel scanning technique.Applied Optics,1995,34(21):4472~4479
  • 9MELLQVIST J, ROSEN A. DOAS for flue gas monitoring--Ⅰ. Temperature effects in the U. V./Visible absorption spectra of NO, NO2, SO2 and NH3 [ J ]. Journal of Quantitative Spectroscopy and Radiative Transfer, 1996,56(2) :187-208.
  • 10MELLQVIST J, ROSEN A. DOAS for flue gas monitoring--Ⅱ. Deviations from the Beer Lambert law for the U. V./Visible absorption spectra of NO, NO2, SO2 and NH3 [ J]. Journal of Quantitative Spectroscopy and Radiative Transfer, 1996,56(2) :209-224.

共引文献105

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部