期刊文献+

股骨远端微创锁定内固定钢板固定参数的三维数字化测量 被引量:10

Three-dimensional digital measurement of fixed parameters of the less invasive stable system fixation
下载PDF
导出
摘要 背景:有研究表明股骨远端微创锁定内固定钢板治疗股骨远端骨折具有较好的疗效,但其设计参数多为参照西方人种数据,且其产品规格有限。目的:对成年中国人中远端股骨微创锁定内固定钢板手术相关解剖CT数据进行数字化测量。方法:选自内蒙古医学院第二附属医院影像科非膝关节疾患的成人CT连续扫描数据15例,利用Mimics10.01软件进行三维重建,在三维立体图形中测量股骨远端宽;股骨外侧髁前后径;股骨外侧髁基底部宽;股骨外侧髁干角;自股骨大转子下缘5cm至外上髁每隔5cm划分为1段,共分为5段,分别测量每段中部股骨内外侧皮质及髓腔横径。结果与结论:成年中国人中远端股骨微创锁定内固定钢板固定后,股骨远端左右侧宽分别为(84.80±1.27)mm和(84.60±1.40)mm;股骨外侧髁前后径分别为(67.36±1.41)mm和(66.27±1.42)mm;股骨外侧髁基底部宽分别为(42.53±3.42)mm和(42.98±1.25)mm;股骨外侧髁干角分别为(7.58±0.69)°和(7.66±0.79)°,左右侧别间差异均无显著性意义。 BACKGROUND:The research has shown that the less invasive stable system(LISS) fixation has good effect on the treatment of distal femoral fractures,but its parameter was according to westerner,and the specification of a manufactured item is limited.OBJECTIVE:To digital measure the related anatomical CT data of LISS fixation in Chinese adults.METHODS:Fifteen cases imaging samples with no disease or osteoporosis were selected from the Second Affiliated Hospital of Inner Mongolia Medical College.The MIMICS10.01 software was used to do the three-dimensional reconstruction,the width of distal femur,anteroposterior diameter of condylus lateralis femoris,basilar part width of condylus lateralis femoris and angle between condylus lateralis femoris and trunk were measured in the three-dimensional images.Every 5 cm was divided into a segment from the 5 cm to the lower edge of the greater trochanter to the lateral epicondyle,five segments in total.The width of internal and lateral cortex and medullary cavity diameter of the femur in the central part of each segments were measured.RESULTS AND CONCLUSION:After LISS fixation in Chinese adults,the width and anteroposterior diameter of condylus lateralis femoris were(84.80±1.27) mm and(67.36±1.41) mm in the left and(84.60±1.40) mm and(66.27±1.42) mm in the right;the basilar part width of condylus lateralis femoris was(42.53±3.42) mm and(42.98±1.25) mm;the angle between condylus lateralis femoris and trunk was(7.58±0.69)° in the left and(7.66±0.79)° in the right,and there was no significant difference between two sides.
出处 《中国组织工程研究》 CAS CSCD 2012年第13期2292-2295,共4页 Chinese Journal of Tissue Engineering Research
  • 相关文献

参考文献13

  • 1Ellis HB,Ho CA,Podeszwa DA. A comparison of locked versus nonlocked enders rods for length unstable pediatric femoral shaft fractures[J].Journal of Pediatric Orthopaedics,2011,(08):825-833.
  • 2Shah S,Kim SY,Dubov A. The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant:cables,screws,or both[J].Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine,2011,(09):845-856.
  • 3Li K,Langdale E,Tashman S. Gender and condylar differences in distal femur morphometry clarified by automated computer analyses[J].Journal of Orthopaedic Research,2012,(05):686-692.
  • 4Connelly CL,Archdeacon MT. the lateral decubitus approach for complex proximal femur fractures:anatomic reduction and locking plate neutralization:a technical trick[J].Journal of Orthopaedic Trauma,2011.
  • 5State Council of the People's Republic of China. Administrative Regulations on Medical Institution[Z].1994.
  • 6Beingessner D,Moon E,Barei D. Biomechanical analysis of the less invasive stabilization system for mechanically unstable fractures of the distal femur:comparison of titanium versus stainless steel and bicortical versus unicortical fixation[J].Journal of Trauma-Injury Infection and Critical Care,2011,(03):620-624.
  • 7盛韶山,邢光霞,潘志军.股骨干骨折髓内钉远端徒手锁钉技术及应用解剖学研究[J].中国骨伤,2007,20(9):605-607. 被引量:9
  • 8Han N,Sun GX,Li ZC. Comparison of proximal femoral nail antirotation blade and reverse less invasive stabilization system-distal femur systems in the treatment of proximal femoral fractures[J].Journal of Orthopaedic Surgery,2011,(01):7-13.
  • 9Beingessner D,Moon E,Barei D. Biomechanical analysis of the less invasive stabilization system for mechanically unstable fractures of the distal femur:comparison of titanium versus stainless steel and bicortical versus unicortical fixation[J].Journal of Trauma-Injury Infection and Critical Care,2011,(03):620-624.
  • 10Hierholzer C,von Rüden C,P(o)tzel T. Outcome analysis of retrograde nailing and less invasive stabilization system in distal femoral fractures:A retrospective analysis[J].Indian J Orthop,2011,(03):243-250.

二级参考文献2

共引文献8

同被引文献115

引证文献10

二级引证文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部