期刊文献+

Swab culture monitoring of automated endoscope reprocessors after high-level disinfection 被引量:1

Swab culture monitoring of automated endoscope reprocessors after high-level disinfection
下载PDF
导出
摘要 AIM:To conduct a bacterial culture study for monitoring decontamination of automated endoscope reprocessors(AERs) after high-level disinfection(HLD).METHODS:From February 2006 to January 2011,authors conducted randomized consecutive sampling each month for 7 AERs.Authors collected a total of 420 swab cultures,including 300 cultures from 5 gastroscope AERs,and 120 cultures from 2 colonoscope AERs.Swab cultures were obtained from the residual water from the AERs after a full reprocessing cycle.Samples were cultured to test for aerobic bacteria,anaerobic bacteria,and mycobacterium tuberculosis.RESULTS:The positive culture rate of the AERs was 2.0%(6/300) for gastroscope AERs and 0.8%(1/120) for colonoscope AERs.All the positive cultures,including 6 from gastroscope and 1 from colonoscope AERs,showed monofloral colonization.Of the gastroscopeAER samples,50%(3/6) were colonized by aerobic bacterial and 50%(3/6) by fungal contaminations.CONCLUSION:A full reprocessing cycle of an AER with HLD is adequate for disinfection of the machine.Swab culture is a useful method for monitoring AER decontamination after each reprocessing cycle.Fungal contamination of AERs after reprocessing should also be kept in mind. AIM:To conduct a bacterial culture study for monitoring decontamination of automated endoscope reprocessors(AERs) after high-level disinfection(HLD).METHODS:From February 2006 to January 2011,authors conducted randomized consecutive sampling each month for 7 AERs.Authors collected a total of 420 swab cultures,including 300 cultures from 5 gastroscope AERs,and 120 cultures from 2 colonoscope AERs.Swab cultures were obtained from the residual water from the AERs after a full reprocessing cycle.Samples were cultured to test for aerobic bacteria,anaerobic bacteria,and mycobacterium tuberculosis.RESULTS:The positive culture rate of the AERs was 2.0%(6/300) for gastroscope AERs and 0.8%(1/120) for colonoscope AERs.All the positive cultures,including 6 from gastroscope and 1 from colonoscope AERs,showed monofloral colonization.Of the gastroscopeAER samples,50%(3/6) were colonized by aerobic bacterial and 50%(3/6) by fungal contaminations.CONCLUSION:A full reprocessing cycle of an AER with HLD is adequate for disinfection of the machine.Swab culture is a useful method for monitoring AER decontamination after each reprocessing cycle.Fungal contamination of AERs after reprocessing should also be kept in mind.
出处 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第14期1660-1663,共4页 世界胃肠病学杂志(英文版)
基金 Supported by The Gastrointestinal Scope Unit of the Chang Gung Memorial Hospital(Kaohsiung)of Taiwan
关键词 监测自动化 消毒机 再加工 内窥镜 文化 细菌培养 真菌污染 Automated endoscope reprocessor Gastrointestinal scope High-level disinfection Swab culture Monitoring Decontamination
  • 相关文献

参考文献14

  • 1Cleaning and disinfection of equipment for gastrointestinal endoscopy. Report of a Working Party of the British Society of Gastroenterology Endoscopy Committee. Gut 1998; 42: 585-593.
  • 2The report of an independent review of endoscope decontamination in northern ireland. 2005. Available from: URL: http://www.dhsspsni.gov.uk/publications/2005/Endo-scope-Report.pdf.
  • 3Guidelines for decontamination of equipment for gastrointestinal endoscopy. 2008. Available from: URL: http://www. bsg.org.uk/clinical-guidelines/endoscopy/guidelinesfor-decontamination-of-equipment-for-gastrointestinalendoscopy.html.
  • 4Chiu KW,Fong TV,Wu KL,Chiu YC,Chou YP,Kuo CM, Chuah SK,Kuo CH,Chiou SS,ChangChien CS. Surveillance culture of endoscope to monitor the quality of high-level disinfection of gastrointestinal reprocessing. Hepatogastroenterology 2010; 57: 531-534.
  • 5Bisset L,Cossart YE,Selby W,West R,Catterson D,O’hara K,Vickery K. A prospective study of the efficacy of routine decontamination for gastrointestinal endoscopes and the risk factors for failure. Am J Infect Control 2006; 34: 274-280.
  • 6Moses FM,Lee J. Surveillance cultures to monitor quality of gastrointestinal endoscope reprocessing. Am J Gastroenterol 2003; 98: 77-81.
  • 7Guidelines on cleaning and disinfection in GI endoscopy. Update 1999. The European Society of Gastrointestinal Endoscopy. Endoscopy 2000; 32: 77-80.
  • 8Reprocessing of flexible gastrointestinal endoscopes. American Society for Gastrointestinal Endoscopy. Gastrointest Endosc 1996; 43: 540-545.
  • 9Pineau L,Villard E,Duc DL,Marchetti B. Endoscope drying/storage cabinet: interest and efficacy. J Hosp Infect 2008; 68: 59-65.
  • 10Chiu KW,Lu LS,Wu KL,Lin MT,Hu ML,Tai WC,Chiu YC,Chuah SK,Hu TH. Surveillance culture monitoring of double-balloon enteroscopy reprocessing with high-level disinfection. Eur J Clin Invest 2011; Epub ahead of print.

同被引文献7

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部