某风力发电机着火原因分析与处理 被引量:4

Fire Cause Analysis and Processing of A Wind Power Generator
下载PDF
导出
摘要 通过对某发电厂火灾事故原因的分析,注意到需要加强风力发电机日常维护,尤其是电控柜下部母排处,可能存在日常工作和维护时遗留下的短接线或其他导体,容易引起690 V母排发生相间短路。因此在日常管理维护中要定期检查风机内各种电气设备接线,发现松动要及时紧固;加强对电缆外观、连接可靠性、电缆桥架胶皮护套是否脱落等全面检查,防止电气短路。 By analyzing the fire cause of a power plant,we clearly recognized that it is need to maintain the wind power generator.The short connection and other conductors left when in maintainence under electronic control cabinet may cause phase fault of 690 v transmitting line.So the connection of electrical equipment should be checked to fasten the looseness of the equipment.To totally check the cable appearance,connection reliability,rubber jacket cable bridge is to prevent electric short circuit.
出处 《电力学报》 2011年第6期527-529,共3页 Journal of Electric Power
关键词 风力发电机 相间短路 火灾事故 wind power generator interphase short circuit fire accident
  • 相关文献

参考文献2

二级参考文献5

  • 1Tande J O, Hunter R. Expert group study on recommended practices for wind turbine testing and evaluation-estimation of cost of energy from wind energy conversion systems[R]. 1994.
  • 2Alexiadis M C, Dokopoulos p S, Sahsamanoglou H S. Wind speed and power forecasting based on spatial mmelagon models [J].Tmnsaclions on Energy Conversion , 1999, 14(3): 836-842.
  • 3Li Shuhui, Wunsch D C, O'Hair E A, et al. Using neural networks to estimate wind turbin~ power generation[J].IEEE Transactions on Energy Conversion, 2001, 16(3): 276-282.
  • 4李俊峰.中国可再生能源技术评价[M].北京:中国环境科学出版社,1999..
  • 5雷亚洲,王伟胜,印永华,戴慧珠.一种静态安全约束下确定电力系统风电准入功率极限的优化方法[J].中国电机工程学报,2001,21(6):25-28. 被引量:107

共引文献57

同被引文献25

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部