摘要
通过对裂解气压缩机中压缸振动异常分析诊断,经过2次的抢修并对转子进行高速动平衡的校验,使压缩机组投入正常运行。
Based on the diagnosis analysis of abnormal vibration of the MP cylinder in cracking gas compressor,the compressor unit works well after two urgent repairs and the highspeed dynamic balancing rotor check.
出处
《乙烯工业》
CAS
2011年第4期49-52,5,共4页
Ethylene Industry
关键词
裂解气压缩机
中压缸
振动
不平衡
Cracking gas compressor
MP cylinder
Vibration
Non - balancing