摘要
介绍了四象限跟踪传感器原理后,分析了存在噪声和死区条件下的四象限探测器的光斑能量探测率、质心探测误差和光斑位移敏感度,推导了此时四象限跟踪传感器跟踪误差的理论公式,并通过实验证明了理论分析的正确性.理论分析和实验的结果都表明,在相同的噪声情况下,质心探测误差和位移敏感度都随着光斑的高斯宽度与死区宽度之比减小而增大,但是位移敏感度增大的趋势要小于质心探测误差增大的趋势,它们共同作用的结果就导致了光斑的高斯宽度与死区宽度之比越大,四象限跟踪探测器的跟踪误差越小.
Based on the basic principle of four-quadrant-based tracking sensor,the energy detecting rate,centroid detecting error and the displacement sensitivity of four-quadrant detector caused by noise or dead zone are analyzed in detail.The tracking error formula of four-quadrant-based tracking senor is put forward theoretically and verified experimentally.The results show that when the noises are constant,the tracking error of four-quadrant-based tracking senor depends on the ration between the width of Gauss facula and the width of dead zone of four-quadrant detector.
出处
《物理学报》
SCIE
EI
CAS
CSCD
北大核心
2012年第7期116-123,共8页
Acta Physica Sinica
关键词
光学工程
跟踪传感器
四象限探测器
噪声分析
optical engineering
tracking sensor
four-quadrant detector
noise analysis