摘要
为了能安全有效地销毁废旧催泪弹,确定最佳的焚烧销毁参数,根据最小自由能法计算了催泪弹药剂在不同温度,空气过量系数分别为1.2、1.4、1.6、1.8、2.0下发生燃烧反应的平衡产物,验证了焚烧炉焚烧法销毁废旧催泪弹的可行性。并对烟气中相关生成物的浓度变化规律进行了研究和讨论,分析确定了催泪弹药剂安全焚烧销毁所需的最佳焚烧温度为1473 K及空气过量系数为1.6。
In order to destroy the waste tear bomb safely and effectively and obtain the optimal parameter of burning destory for tear bomb.Minimum free energy method is adopted to calculate the equilibrium products of combustion from the combustion of the tear bomb at diffierent temperatures and excess air rate.Though it,the way of destroying waste tear gas in incinerator is proved to be feasible.In this paper,the variable concentration of the correlative resultant of the gas is analyzed,the proper temperature is 1047 K and excess air rate is 1.6 which are required by the safe and eddective incineration of the tear bomb.
出处
《含能材料》
EI
CAS
CSCD
北大核心
2012年第2期218-222,共5页
Chinese Journal of Energetic Materials
关键词
军事装备学
最小自由能
催泪弹
焚烧温度
空气过量系数
military equipment
free-energy minimization
tear gas
burning temperature
excess air coefficient