摘要 目的 分析准分子激光原位角膜磨削术(LASIK)后非接触式眼压(NCT)的改变及其相关因素。方法 对术前屈光度为-375~-2450D的患者82例146眼行LASIK治疗,观察6个月以上。手术前后予以NCT等检查,比较术前术后NCT的改变及其相关因素。结果 术前NCT平均值:(1677±271)mmHg。术后:(1376±263)mmHg。差异有显著性。相关系数分别为039,028。结论 LASIK后NCT读数值下降,下降值与实矫屈光度和角膜曲率改变值有相关性,判断眼压时要将读数下降值作为修正值附加上去。 ObjectiveTo assess the changes and relative factors of noncontact tonometer(NCT) after laser in situ keratomileusis (LASIK).MethodsThe database of patients who had LASIK was retrospectively reviewed.Preoperative and postoperative intraocular pressures(IOPs) were measured in 146 eyes (82 patients).The correlation between decrease in IOP and various preoperative and intraoperative parameters was evaluated by regression analysis.ResultsIOP measured with NCT was reduced at the postoperative stage ( u =9 63, P <0 01) The mean IOP reduction after LASIK was (6.02±3.61)mmHg,and the normal range of IOP reduction after LASIK is 0~11 59*!mmHg.There was correlation between decrease in IOP by NCT and actual refraction changes or between decrease in IOP and curvature changes.Regression equation for NCT drop (mmHg)=0 30*!A+2 93[A=actual refraction change(D)].ConclusionIOP measured with NCT was reduced at the postoperative stage after LASIK.It was related to the corneal changes.We should take care about it to prevent or control corticosteroid induced glaucoma and/or ocular hypertension at the postoperative stage after LASIK.It also may be important in the management of any future glaucoma.
出处 《眼科研究》 CSCD 2000年第1期66-68,共3页 Chinese Ophthalmic Research
关键词 准分子激光 原位角膜磨削术 眼压 NCT laser in situ keratomileusis intraocular pressure
  • 相关文献

参考文献1

二级参考文献2

  • 1周激波,中国实用眼科杂志,1998年,16卷,184页
  • 2王造文,中华眼科杂志,1995年,31卷,172页

共引文献5

同被引文献21

  • 1倪焰,孙建宁,魏春惠,栾洁.近视眼屈光、角膜厚度与眼压三者间的相关分析[J].眼科新进展,2004,24(4):289-290. 被引量:16
  • 2吴苗琴,徐志能,洪朝阳.LASIK术眼角膜厚度与眼压及屈光度相关性研究[J].眼外伤职业眼病杂志,2005,27(10):744-746. 被引量:8
  • 3Lleo A,Marcos A,Calatayud M,Alonso L,Rahhal SM,Sanchis-Gimeno JA.The relationship between central corneal thickness and Goldmann applanation tonometry[J].Clin Exp Optom 2003;86(2):104-108.
  • 4Whiteacre MM,Srein RA,Hassanein K.The effect of corneal thickness on applanation tonometry [J].Am J Ophthalmol 1993; 115:592-596.
  • 5Chatterjee A,Shah S,Bessant DA,Naroo SA,Doyle SJ.Reduction in intraocular pressure after excimer laser photorefractive keratectomy [J].Ophthalmology 1997;104:355-359.
  • 6Argus WA.Ocular hypertension and central corneal thickness[J].Ophthalmology 1995; 102:1810-1812.
  • 7Brandt JD.Corneal thickness in glaucoma screening,diagnosis,and management [J].Curr Opin Ophthalmol2004; 15(2) :85-89.
  • 8Nomura H,Ando F,Niino N,Shimokata H,Miyake Y.The relationship between intraocular pressure and refractive error adjusting for age and central corneal thickness[J].Ophthalmic Physiol Opt 2004; 24 (1):41-45.
  • 9Stone RA,Flitcroft DI.Ocular shape and myopia[J].Ann Acad Med Singapore 2004;33:7-15.
  • 10Stone RA,Liu J,Sugimoto R,Capehart C,Zhu X,Pendrak K.Experimental myopia and ocular growth in chick [J].In vest Ophthalmol Vis Sci 2003; 44:3933-3946.

引证文献3

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部