摘要
针对现有矿热炉水冷保护套的结构不足,提出一种新型的矿热炉水冷保护套结构,并采用流体有限元分析软件FLUENT对新型水冷保护套的结构进行优化设计,最终提出一种合理的结构,该结构在实际应用中取得了良好的效果。
A new-style water cooling protective jacket structure of submerged arc furnace was designed according to practical experiences of existing insufficient structures,and applied liquid finite element analysis software FLUENT to optimize structure of the new-style water cooling protective jacket,finally advanced a effective improved structure and achieved good results.
出处
《工业加热》
CAS
2012年第2期74-76,共3页
Industrial Heating
关键词
矿热炉
水冷保护套
结构
FLUENT有限元分析
优化设计
submerged arc furnace
water cooling protective jacke
structure
FLUENT finite element analysis
optimization design