摘要 激光三角法是一种几何测量的重要方法 ,目前已广泛用于测量位移和三维面形 ,但该测量系统的测量精度不高 ,一个主要的问题就是光源光强不稳定 ;本文提出用光学双稳装置来稳定激光光源的光强 ,并用于测量金属板材 ,实验结果表明 :将光学双稳装置用于激光三角法使系统的测量精度大大提高。 Laser triangle method is a very important geometrical method in measuring displacement and 3-D profile,but the measuring accuracy is lower in laser triangle method,and a mian question is unstability of laser light power.This paper suggested to stable the output light intensity by using the bistable optical device and used this new device to measure the thickness of metal plate.The experimental results show the novel system is better than the traditional triangulation system clearly.
出处 《激光杂志》 CAS CSCD 北大核心 2000年第3期54-55,共2页 Laser Journal
关键词 光学双稳装置 激光三角法 测量精度 bistable optical device,laser triangle method,the thickness of metal plate,measuring accuracy