摘要
介绍了快开式隔膜压滤机的结构及工作原理,结合实际运行中出现的故障现象进行了原因分析,并通过现场试验性的改造,给出了相应的处理方法。此项改造在实际生产应用中取得了良好的效果,有效降低了快开式隔膜压滤机的故障率,为同类型的快开式隔膜压滤机实际检修应用提供了借鉴。
Introduces the structure and the working principle of the quick open membrane press filter,combines with the fault phenomenon occurred in the actual operation and analyzes the reasons,through reforming in the field experiment,gives the corresponding processing method.The transformation achieves good effects in the actual production,effectively reduces the failure rates of quick open membrane press filter,for the same type of quick open membrane press filter provides the reference in actual maintenance and application.
出处
《山西焦煤科技》
2012年第3期42-43,56,共3页
Shanxi Coking Coal Science & Technology
关键词
快开式隔膜压滤机
改造
故障分析
处理方法
Quick open membrane press filter
Modification
Failure analysis
Processing method