摘要 质谱分析具有灵敏度高、样品用量少、分析速度快等优点[1]。对于表征有机化合物而言,第一步和最重要的步骤就是快速准确地确定相对分子质量,电喷雾电离四极杆质谱恰好满足了这样的要求,成为药物化学合成实验不可缺少的检测工具之一。本文中用到的质谱是Waters公司的型号为Quattro microTMAPI的电喷雾电离四极杆质谱,它的可测质荷比范围为2~2 000 m/z,适用于小分子化合物检测,所以可用于药物化学实验反应中间产物、目标化合物以及副产物的定性检测。
出处 《首都医科大学学报》 CAS 2012年第2期271-274,共4页 Journal of Capital Medical University
基金 首都医科大学校长基金(11GLY04)~~
  • 相关文献

参考文献10

二级参考文献63

共引文献18

同被引文献19

  • 1Dai Z, Wu Z, Jia S, et al. Analysis of amino acid composition in proteins of animal tissues and foods as pre-column o-phthaldialdehyde derivatives by HPLC with fluorescence detection [J]. J Chromatogr B Analyt Technol Biomed Life Sci, 2014, 3: 1-12.
  • 2Buiarelli F, Gallo V, Di Filippo P, et al. Development of a method for the analysis of underivatized amino acids by liquid chromatography/tandem mass spectrome- try: application on Standard Reference Material 1649a (urban dust)[J]. Talanta, 2013, 115(15): 966-72.
  • 3Petritis KN, Chaimbauh P, Elfakir C ,et al. Ion-pair reversed-phase liquid chromatography for determination of polar underivatized amino acids using perfluorinated carboxylic acids as ion pairing agent [J]. J Chromatogr A, 1999, 833(2): 147-55.
  • 4Kwon JY, Moini M. Analysis of underivatized amino acid mixtures using high performance liquid chromatography/ dual oscillating nebulizer atmospheric pressure microwave induced plasma ionization-mass spectrometry [J]. J Am Soc Mass Spectrom, 2001, 12(1): 117-22.
  • 5Harder U, Koletzko B, Peissner W. Quantification of 22 plasma amino acids combining derivatization and ion- pair LC-MS/MS [J]. J Chromatogr B Analyt Technol Biomed Life Sci, 2011, 879(7-8): 495-504.
  • 6Aruda W, Aruda K. Review of volatile perfiuorocar- boxylic acids as ion pair reagents in LC [J]. Lc gc north america, 2009, 10: 919-27.
  • 7Kotrebai M, Tyson JF, Block E, et al. High-performance liquid chromatography of selenium compounds utilizing perfluotinated carboxylic acid ion-pairing agents and in- ductively coupled plasma and electrospray ionization MS detection[J]. J Chromatogr A, 2000, 866(1): 51-63.
  • 8Chaimbauh P, Petritis K, Elfakir C, et al. Ion-pair chromatography on a porous graphitic carbon stationary phase for the analysis of twenty underivatized protein amino acids[J]. J Chromatogr A, 2000, 870(1-2): 245-54.
  • 9Orioli M, Aldini G, Benfatto MC, et al. HNE Michael adduets to histidine and histidine-containing peptides as biomarkers of lipid-derived carbonyl stress in urines: LC-MS/MS profiling in Zucker obese rats[J]. Anal Chem, 2007, 79(23): 9174-84.
  • 10Le A, Ng A, Kwan T, et al. A rapid, sensitive method for quantitative analysis of underivatizedamino acids by liquid chromatography-tandem mass spec- trometry (LC-MS/MS)[J]. J Chromatogr B Analyt Technol Biomed Life Sci, 2014, 944: 166-74.