Relationship between the Alignment of a Non-Mydriatic Fundus Camera,Anterior Chamber Depth and Axial Length

Relationship between the Alignment of a Non-Mydriatic Fundus Camera,Anterior Chamber Depth and Axial Length
下载PDF
导出
摘要 Purpose:To evaluate the relationship between the position of the focal adjustment knob of a fundus camera and refractive error and biometric data as measured in the same eye.Methods:Normal eyes of patients presenting to clinics at the Beijing Tongren Hospital were examined with a non-mydriatic fundus camera.The position on the focal scale of a knob adjusting the distance between the camera lens and film plane,used to adjust focus the image of the patients fundus relative to the refractive power of the eye,was recorded in degrees.Ocular biometry and refractometry were performed on the same eyes.Results:The study included 136 subjects with a mean age of 36.5 ±19.6 years and a mean refractive error of-1.31 ±2.77 diopters.In univariate analysis,the position of the adjustment knob was significantly associated with refractive error.(P < 0.001;correlation coefficient r=-0.77),axial length.(P<0.001;r=0.65) and anterior chamber depth (P<0.001;r=0.48).After adjustment for age,anterior chamber depth decreased by 0.01 mm(95% confidence interval:0.003,0.017) for change per degree in the position of the adjustment knob.Conclusion:A fundus camera can be used to estimate anterior chamber depth,axial length and refractive error.In a screening setting,a fundus camera operated by a technician may be helpful to detect a shallow anterior chamber and evaluate a potential risk factor for primary angle closure. Purpose: To evaluate the relationship between the position of the focal adjustment knob of a fundus camera and refractive error and biometric data as measured in the Same eyel Methods: Normal eyes of patients presentingto clinics at the Beijing Tongren Hospital were examined with a non-mydriatic fundus camera. The position on the focal scale of a knob ad- justing the distance between the camera lens and film plane, used to adjust focus the image of the patients fundus relative to the refractive power of the,eye, was recorded in degrees. Ocular biometry and refractometry were performed on the same eyes. Results: The study included 136 subjects with a mean age of 36.5___19.6 years and a mean refractive error of -1.31 +2.77 diopters. In univariate analysis, the position of the adjustment knob was significantly associated with refractive error (P〈 0.001; correlation coefficient r=-0.77), axial length (P〈0.001 ; r=0.65) and anterior chamber depth (P〈0.001;r=0.48). After adjustment for age, anterior chamber depth decreased by 0.01 mm (95% confidence interval: 0.003,0.017) for change per de- gree in the position of the adjustment knob. Conclusion: A fundus camera can be used to estimate anterior chamber depth, axial length and refractive error. In a screening setting, a fundus camera operated by a technician may be helpful to detect a shallow anterior chamber and evaluate a potential risk factor for primary angle closure.
出处 《Eye Science》 2012年第1期30-33,共4页 眼科学报(英文版)
关键词 眼底照相机 长度 调节旋钮 屈光不正 对准 平均年龄 生物测量 angle-closure glaucoma fundus camera anterior chamber depth hyperopia
  • 相关文献

参考文献16

  • 1Colenbrander A.Principles of ophthalmoscopy.In:Du-ane T(ed)Clinical Ophthalmology.Vol1.Philadelphia,1991:1-21.
  • 2Wong D.The fundus camera.In:Duane T(ed)Clinical Ophthalmology.Vol1.Philadelphia,1991:1-8.
  • 3Bengtsson B,Krakau CET.Some essential optical fea-tures of the Zeiss fundus camera..Acta Ophthalmol,1977;55:123-131.
  • 4Michael GQ,Pascale D.A new fundus camera technique to help calculate eye camera magnification.Arch Oph-thalmol,2003;121:707-709.
  • 5Grewal DS,Brar GS,Jain R,et al.Comparison of Scheimpflug imaging and spectral domain anterior seg-ment optical coherence tomography for detection of nar-row anterior chamber angles.Eye,2011;25:603-611.
  • 6Park SB,Sung KR,Kang SY,et al.Assessment of nar-row angles by gonioscopy,Van Herick method and an-terior segment optical coherence tomography.Jpn J Oph-thalmol,2011;55:343-350.
  • 7Massin P,Erginay A,Ben MA,et al.Evaluation of a new non-mydriatic digital camera for detection of diabet-ic retinopathy.Diab Med,2003;20:635-641.
  • 8Vujosevica S,Benettib E,Massignanb F,et al.Screen-ing for diabetic retinopathy:1and3nonmydriatic45-degree digital fundus photographs vs7standard early treatment diabetic retinopathy study fields.Am J Oph-thalmol,2009;148:111-118.
  • 9Williams GA,Scott IU,Haller JA,et al.Single-field fundus photography for diabetic retinopathy screening:a report by the American Academy of Ophthalmology.Ophthalmology,2004;111:1055-1062.
  • 10Zimmer-Galler LE,Zeimer R.Feasibility of screening for high-risk age-related macular degeneration with an internet-based automated fundus camera.Ophthalmic Surg,Lasers&Imaging,2005;36:228-236.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部