摘要 介绍了稳高压消防给水系统与临时高压消防给水系统的定义,进行了两类消防给水系统的对比,对火电厂稳高压消防给水系统水泵接合器及消防水箱的设置提出建议。 The definitions of stabilized high pressure fire fighting water supply system and temporary high pressure fire fighting water supply system were introduced,and a comparison between the two systems was carried out.Some suggestions for the setup of pump adapters and fire water tanks of stabilized high pressure fire fighting water supply system in thermal power plant were pointed out.
作者 赵佰波 王欣
出处 《工业用水与废水》 CAS 2012年第2期86-88,共3页 Industrial Water & Wastewater
关键词 消防给水系统 稳高压 临时高压 水泵接合器 消防水箱 fire fighting water supply system stabilized high pressure temporary high pressure pump adapter fire fighting water tank
  • 相关文献

参考文献3

二级参考文献6

  • 1GB5016-92,石油化工企业设计防火规范[S].
  • 2GB50229-96.火力发电厂与变电所设计防火规范[S].[S].,..
  • 3DL50000-94,火力发电厂设计技术规程[S].
  • 4S2,给水排水标准图集/消防设备安装[S].
  • 5GB50160-92 1999.石油化工企业设计防火规范[s].[S].中国石油化工总公司,..
  • 6GB50045-95.高层民用建筑设计防火规范[S].[S].中华人民共和国公安部,..