摘要
介绍了稳高压消防给水系统与临时高压消防给水系统的定义,进行了两类消防给水系统的对比,对火电厂稳高压消防给水系统水泵接合器及消防水箱的设置提出建议。
The definitions of stabilized high pressure fire fighting water supply system and temporary high pressure fire fighting water supply system were introduced,and a comparison between the two systems was carried out.Some suggestions for the setup of pump adapters and fire water tanks of stabilized high pressure fire fighting water supply system in thermal power plant were pointed out.
出处
《工业用水与废水》
CAS
2012年第2期86-88,共3页
Industrial Water & Wastewater
关键词
消防给水系统
稳高压
临时高压
水泵接合器
消防水箱
fire fighting water supply system
stabilized high pressure
temporary high pressure
pump adapter
fire fighting water tank