期刊文献+

三种牙本质黏结剂从涂布到光固化挥发时间对其微拉伸强度的影响

Effects of Volatilization Time of Three Dentin Adhesives before Light Curing on Micro-tensile Bond Strength to Dentin
下载PDF
导出
摘要 目的比较和评价Gluma One-Bond(OB)、Single Bond(SB)和Clearfil SE Bond(SE)3种黏结剂从涂布到光固化挥发暴露时间对其微拉伸强度的影响,得出时间量化指标,为临床操作提供参考。方法采用微拉伸强度测试法比较3种牙本质黏结剂(OB,SB和SE)分别涂布10,20,30,40和50s后的微拉伸强度,并在扫描电镜下观察断面微观形态。结果 OB、SB和SE 10s组的微拉伸强度值明显低于20s组、30s组、40s组与50s组,差异有统计学意义,20s后微拉伸强度达峰值,之后结果保持稳定,后4组的微拉伸强度均值间无统计学意义。扫描电镜下观察发现,3种黏结剂的20s组、30s组、40s组和50s组牙本质小管口的封闭情况都比10s组好;SE中20s组、30s组、40s组和50s组均比OB和SB中相应秒组的牙本质小管口封闭情况要好。结论 3种黏结剂从涂布到光固化暴露挥发时间从20s后即可获得理想的黏结强度。 Objective To develop quantitative indicators for evaluating the effects of volatilization time of three dentin adhesive systems before light curing on microtensile bond strengths,and to provide a reference for clinical treatment.Methods The microtensile bond strengths of three different dentine adhesives(Gluma One-Bond,Single Bond and Clearfil SE Bond) were determined by microtensile bond test at 10,20,30,40 and 50 seconds after the application of adhesive coating.The interface of fractured bond was observed by scanning electron microscopy(SEM).Results Microtensile bond strength at 10 seconds after adhesive coating was significantly lower than that at 20,30,40 and 50 seconds after adhesive coating for all three adhesives.The peak values of microtensile bond strength were obtained after 20 seconds and differences were not significant among values after 20,30,40 and 50 seconds.SEM showed that occluding situations of dentinal tubules at 20,30,40 and 50 seconds after adhesive coating were better than those at 10 seconds after adhesive coating and Clearfil SE Bond specimens had better occluding situations than Gluma One-Bond and Single Bond specimens.Conclusions The desired dentin bond strength can be achieved by volatilization time of at least 20 seconds.
作者 罗璇 张晓晞
出处 《南昌大学学报(医学版)》 CAS 2012年第1期41-44,共4页 Journal of Nanchang University:Medical Sciences
关键词 牙本质黏结剂 挥发时间 微拉伸强度 对比研究 dentin adhesive volatilization time microtensile bond strength comparative study
  • 相关文献

参考文献11

  • 1Nakabayashi N,Kojima K,Masuhara E. The promotion of adhesion by the infiltration of monomers into tooth substrates[J].Journal of Biomedical Materials Research,1982,(03):265-273.doi:10.1002/jbm.820160307.
  • 2Marshall S J,Bayne S C,Baier R. A review of adhesion science[J].Dental Materials,2010,(02):e11-e16.
  • 3Alessandra R,Paula De,Vieira L C. Effect of prolonged application times on the durability of resin-dentin bonds[J].Dental Materials,2008,(06):639-644.
  • 4Han L,Bakr N,Okamoto A. WDX study of resin-dentin interface on wet vs.dry dentin[J].Dental Materials,2000,(03):317-325.
  • 5李潇,吴新荣,段建民,汪维健.效前挥发对含有不同溶剂的粘接剂微拉伸强度的影响[J].现代口腔医学杂志,2008,22(2):192-194. 被引量:3
  • 6De Munek J,Van Landuyt K,Peumans M. A critical review of the durability of adhesion to tooth tissue:methods and results[J].Journal of Dental Research,2005,(02):118-132.
  • 7Senawonqse P,Srihanon A,Muanqminqsuk A. Effect of dentine smear layer on the performance of self-etching adhesive systems:A micro-tensile bond strength study[J].Journal of Biomedical Materials Research Part B:Applied Biomaterials,2010,(01):212-221.
  • 8Nishitani Y,Yoshiyama M,Hosaka K. Use of Hoy's solubility parameters to predict water sorption/solubility of experimental primers and adhesives[J].European Journal of Oral Sciences,2007,(01):81-86.doi:10.1111/j.1600-0722.2007.00430.x.
  • 9Krishna M,Kundabala M,Rashmi A. Effect of saliva contamination and decontamination procedures on shear bond strength of self-etch dentine bonding system:A in vitro study[J].J Conserv Dent,2010,(02):71-75.
  • 10张明,冯岩,黄晓晶,雷丽珊,郑碧琼,卢友光.自酸蚀牙本质粘接剂对人牙髓成纤维细胞的毒性作用[J].华西口腔医学杂志,2008,26(1):94-97. 被引量:9

二级参考文献26

  • 1李潇,赵信义,施长溪,李洪涛.表面状态对酒精—水基粘接剂粘接界面影响的研究[J].现代口腔医学杂志,2004,18(6):507-509. 被引量:4
  • 2Dumsha TC,Sydiskis RJ.Cytotoxicity testing of a dentin bonding system[J].Oral Surg,1985,59(6):637-641
  • 3Douglas WH.Clinical status of dentine bonding agents[J].J Dent,1989,17(5):209-215
  • 4al-Dawood A,Wennberg A.Biocompatibility of dentin bonding agents[J].Endod Dent Traumatol,1993,9(1):1-7
  • 5Dumsha TC,Beckerman T.Pulp response to a dentin bonding system in miniature swine[J].Dent Mater,1986,2(4):156-158
  • 6Huang FM,Chang YC.Cytotoxicity of dentine-bonding agents on human pulp cells in vitro[J].Int Endod J,2002,35(11):905-909
  • 7Hebling J,Giro EM,Costa CA.Human pulp response after an adhesive system application in deep cavities[J].J Dent,1999,27(8):557-564
  • 8Hebling J,Giro EM,Costa CA.Biocompatibility of an adhesive system applied to exposed human dental pulp[J].J Endod,1999,25(10):676-682
  • 9Demarco FF,Tarquinio SB,Jaeger MM,et al.Pulp response and cytotoxicity evaluation of 2 dentin bonding agents[J].Quintessence Int,2001,32(3):211-220
  • 10Schmalz G,Schuster U,Koch A,et al.Cytotoxicity of low pH dentin-bonding agents in a dentin barrier test in vitro[J].J Endod,2002,28(3):188-192

共引文献10