摘要 采用便携式分光光度计对水环境中的氰化物进行应急监测.结果表明:在严格控制实验过程中的温度为24~25℃,试剂加入后使用黑布避光30min的条件下,可较准确测定0.005~0.100mg.L-1浓度范围内的样品溶液,测定值的相对误差和所占标准值比例的误差均≤20%.本研究为水环境中氰化物的快速测定提供了理论依据,并在一定程度上加强了水环境应急监测的现场分析能力. A new method using portable spectrophotometry has been established in order for emergency monitoring of Cyanide in water. The Cyanide was quickly determined after reagents was added and held in the dark for 30 rain. During this process, temperature was strictly controlled between 24--25 ℃. The linear range of the method is 0. 005 to 0. 100 mg/L, the relative standard deviation between the measured results is less than 20 %. This study provides a theoretical basis for the rapid determination of cyanide in the aquatic environment and strengthens analysis ability for emergency monitoring on site to some extent.
出处 《河南师范大学学报(自然科学版)》 CAS CSCD 北大核心 2012年第2期118-121,共4页 Journal of Henan Normal University(Natural Science Edition)
基金 河南省基础与前沿技术研究项目(102300410193 102300410196) 河南省创新型科技人才队伍建设工程项目
关键词 氰化物 应急监测 分光光度计 cyanidel emergency monitoring spectrophotometry
  • 相关文献

参考文献11

二级参考文献17

  • 1江义平,敖小平,王良恩.高浓度氰化物废水处理的研究和应用[J].工业用水与废水,2005,36(2):43-45. 被引量:14
  • 2余万俊,鲁长豪,肖志芳,牟家婉,蒋中华.单克隆抗体酶免疫分析法测定大米中杀虫脒残留量[J].环境科学,1995,16(4):51-53. 被引量:14
  • 3李俏颖.氰化物突发性泄漏污染事故的应急监测[J].福建分析测试,2007,16(2):55-58. 被引量:5
  • 4[5]顾友多.江河内氰化钠泄漏事故应急处理的有关科学依据[EB/OL].http://www.chemaid.com/CN-SPILL.htm,2001-11-12.
  • 5[7]国家环境保护局.水和废水检测分析方法(第三版)[M].北京:中国环境科学出版社,1992.315-316.
  • 6[8]国家环境保护局.环境检测分析方法(第四版)[M].北京:中国环境科学出版社,1993.94.
  • 7刘曙照.极谱定量分析法-底液的选择[J].分析科学学报,2000,(5):170.
  • 8环境污染事故应急预案与处理处置案例[M].北京:中国环境科举出版社,2007.
  • 9境亨 孙铁珩 译.分析化学[M].北京:中国建筑工业出版社,1987.118-119.
  • 10吴乾丰.双波长分光光度法测定微量氰[J].分析化学,1999,(1):21-22.

共引文献1903

同被引文献28

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部