摘要 目前建筑防排烟系统的常规设计尚存不足,对于无吊顶或镂空吊顶形式的空间,排烟口的开设方式被忽略。针对该类空间,该文进行了优化设计研究,提出了排烟口的开设不应只拘泥于常规设计中面向地面的向下排烟口,而应该更多考虑采用侧向排烟口和面向顶棚的向上排烟口。数值模拟结果比较表明:侧向排烟口和向上排烟口与常规设计的向下排烟口相比,烟气控制效果显著改善;其中向上排烟口获得的烟气控制效果最好,挡烟垂壁高度得以减小;优化设计方案可行且更加经济合理,提高了消防安全性。 Conventional designs of building smoke extraction systems are usually quite simple due to the complex structures. For spaces without ceilings or with hollow ceilings, most analyses ignore the actual geometry of the exhaust inlets. This study analyzes the effects of exhaust inlet placement to show that side exhaust inlets and upward facing exhaust inlets should be taken into account, instead of only the conventional down facing vents. Simulations show that the smoke control effects of the side exhaust inlets and upward facing exhaust inlets are even more important than the conventional down vents. The smoke control effects of upward facing exhaust inlets are the best so smoke curtains can be shortened with the vent design being more economical.
出处 《清华大学学报(自然科学版)》 EI CAS CSCD 北大核心 2012年第4期532-535,共4页 Journal of Tsinghua University(Science and Technology)
基金 国家“九七三”重点基础研究项目(2012CB719700)
关键词 无吊顶 镂空吊顶 排烟口 挡烟垂壁 优化 non ceiling hollow ceiling exhaust inlet smokecurtain optimization design
  • 相关文献

参考文献6

  • 1Gann R G.Estimating data for incapacitation of people by firesmoke[J].Fire Technology,2004,40(2):201-207.
  • 2Jin T.Visibility and human behavior in fire smoke[M] //SFPE Handbook of Fire Protection Engineering,third ed.National Fire Protection Association,Quincy,MA,2002.
  • 3NFPA92B,Guide for Smoke Management Systems in Mall,Atria,and Large Areas 2000 Edition[R].National FireProtection Association,2000,USA.
  • 4GB50045—95,高层民用建筑设计防火规范[S].北京:中国计划出版社.2005.
  • 5GB50016-2006建筑防火设计规范[S].北京:中国计划出版社,2006.
  • 6DGJ08-88-2006.民用建筑防排烟技术规程[S].上海,2006.

共引文献30

同被引文献9

  • 1高俊霞,史聪灵,钟茂华.深埋地铁防排烟设计研究[J].中国安全生产科学技术,2006,2(6):39-44. 被引量:16
  • 2王彦富,蒋军成.地铁火灾人员疏散的研究[J].中国安全科学学报,2007,17(7):26-31. 被引量:35
  • 3GB50116-2013火灾自动报警系统设计规范[S].北京:中国计划出版社,2013.
  • 4GB 50517-2013,地铁设计规范[S].北京:中国建筑工业出版社’2013.
  • 5Manabu Tsukahara, Yusuke Koshibab, Hideo Ohtani. Effectivenessof downward evacuation in a large-scale subway fire using Fire Dy-namics Simulator [J]. Tunnelling and Underground Space Technol-ogy, 2011,26:573-581.
  • 6Na Luo, Angui Li, Ran GAO, Tongyang Song, Wei Zhang, ZhipeiHu. Performance of smoke elimination and confinement with modi-fied hybrid ventilation for subway station [ J ]. Tunnelling and Un-derground Space Technology,2014 , 43 : 140-147.
  • 7McGrattan K. Fire Dynamics Simulator Technical Reference Guide[M]. Version 5. 0 NIST Special Publication. Gaithersburg, Mary-land: National Institute of Standards and Technology, 2005.
  • 8陈南.悬空式格栅吊顶场所感烟火灾探测报警试验研究[J].火灾科学,2012,21(4):216-224. 被引量:5
  • 9翟毅.镂空吊顶对吸气式感烟火灾探测器的影响研究[J].建筑电气,2014,33(11):62-66. 被引量:2

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部