双通道经颅多普勒超声检测机械心瓣膜患者微栓子信号

Detection of microembolic signals using bigated transcranial Doppler in patients with mechanical heart valve
下载PDF
导出
摘要 目的 :观察脑动脉微栓子信号 (MES)的基本特征 ,结合 TCD- 8软件分析检测 MES的敏感性和特异性。方法 :采用双通道 TCD和 TCD- 8软件检测 4例机械心瓣膜患者的脑动脉 MES。结果 :2例发现 MES信号 ,MES相对强度为 14~34 (2 6 .5± 4.9) d B,时间延迟为 0 .5~ 2 0 .3(中位数为 5 .3) ms,TCD- 8软件检测 MES的敏感性为 6 4.2 0 % ,特异性为 6 9.33%。结论 :双通道 TCD不仅是研究 MES基本特征的有效方法 ,也为识别、检测 MES提供了新方法 ,但在线状态下人工判断仍是必需的。 Objectiev:To study the basic characteristics of cerebral arterial microembolic signals (MES),and analyze the sensitivity and specificity of detection of MES using bigated transcranial Doppler(TCD) Method:the MES were detected using bigated transcranial Doppler(TCD) in 4 patients with mechanical heart valve Results:MES were detected in 2 patients MES relative intensity was 14~34(26 5±4 9)dB,the time was delayed 0 5~20 3(median 5 3)ms Bigated TCD presented sensitivity of 64 20% and specificity of 69 33% Conclusion:Bigated TCD is a valuable way to study the basic characteristics of MES We think that bigated TCD adds a new dimension detecting MES,but detection of MES on line depends on an experienced investigator
出处 《广西医学》 CAS 2000年第2期238-240,共3页 Guangxi Medical Journal
关键词 双通道 经颅多普勒 微栓子信号 人工心瓣膜 Bigated transcranial Doppler Microembolic Signals Mechanical heart valve
  • 相关文献

参考文献11

  • 1Spencer MP, Thomas GI, Nieholls SC, et al. Detection of middle cerebral artery emboli during cardotid endarterectony using transcranial Doppler ultrasonography. Stroke 1990;21(3):415
  • 2Daffertshofer M,Ries S,Schminke U,et al. High-intensity transient signals in patients with cerebral ischemia. Stroke 1996;27(10):1844
  • 3Del Sette M, Angeli S, Stara I, et al. Microembolic signals with serial transcranial Doppler monitoring in acute focal ischemic edlieit. A local phenomenon? Stroke 1997;28(7):131
  • 4Consensus Committee of the 9th International Cerebral Hemodynamic Symposium. Basic identification criteria of Doppler microembolic signals. Stroke 1995;26(6):1123
  • 5Georgiadis D, Wenzel A, Lehmarm D. et al. Influencce of oxygen ventilation on Doppler microemboli signals in patients with artificial heart valves. Stroke 1997;28(1): 2189
  • 6Shu Mc, Gross JM, Johnso KM. Can cavitation bubbles generated by mechanical heart valves be detected by transcranial Doppler? J Heart Valve Dis 1995;4:542
  • 7Droste DW, Hagedorn G, Notzold A, et al. Bigated transcranial Doppler for the detection of clinically silent circulating emboli in normal persons and patients with prosthetic cardiac vaves. Stroke 1997;28(3):588
  • 8倪秀石,朱文辉,王淦.双门深TCD检测脑动脉微栓子信号的敏感性和特异性[J].中国超声医学杂志,1999,15(5):361-364. 被引量:3
  • 9Markus Hs,Thomson N,Brown MM,et al. Asymptomatic cerebral embolic signals in symptomatic and asymptomatic carotid artery disease. Brain 1995;118(4):1005
  • 10Grosset DG,Georgiadis D,Kelman AV,et al. Quantification of ultrasound embolic signals in patients with cardiac and carotid disease. Stroke 1993; 24:1922

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部