摘要 目的:利用计算机辅助设计与快速成形技术为儿童胸椎椎弓根螺钉置入提供一种个性化、精确定位的方法。方法:对4具胸椎尸体标本进行CT扫描,根据CT扫描资料,利用逆向工程原理及快速成型技术设计制造出个体化导航模板,利用个体化导航模板在尸体标本上辅助置入胸椎椎弓根螺钉,所有螺钉的置入由同一位具有腰椎椎弓根螺钉置钉经验但无胸椎椎弓根螺钉置钉经验的骨科医师进行操作,随后根据CT扫描评价椎弓根螺钉位置。结果:共设计制作48个导航模板,辅助置入96枚胸椎椎弓根螺钉,CT扫描发现所有螺钉均准确置入相应椎弓根内。结论:数字化导航模板辅助胸椎椎弓根螺钉置钉准确性高,操作简单,为儿童胸椎椎弓根螺钉的准确置入提供了一种新的、可行方法。 Objective: To provide a new method in the accuracy of pedicle screw placement in tho- racic vertebraes of Child using computer - aided design. Methods: A novel individual navigation tem- plate was developed by reverse engineering and rapid prototyping according to pre - operative CT data of six Child thoracic vertebraes. The templates were used for thoracic vertehraes screw placement in the cadavers. All screws were implanted by an experienced orthopaedic surgeon in the lumbar spines but not in the thoracic vertebraes. Subsequently, CT scan were performed to evaluate the screw orientation associated with the pedicle axis. Results:96 thoracic pedicle screws assisted by 48 digital navigation templates were placed in thoracic vertebras. CT scan findings showed all screws were accurately nailed into the corresponding pedicles. Conclusion: Pedicle screw placement assisted by digital navigation templates is highly accurate and simple. It is a new alternative to thoracic pedicle stereotaxy of child.
出处 《内蒙古医学院学报》 2012年第2期99-103,共5页 Acta Academiae Medicinae Neimongol
基金 国家自然科学基金资助项目(81160229) 内蒙古自治区自然科学基金项目(2010MS1106) 内蒙古自治区高等学校科学研究课题(NJ10132)
关键词 数字化 个体化导航模板 儿童 胸椎 椎弓根 digital individual navigation template child thoracic vertebraes thoracic pedicle
  • 相关文献

参考文献19

  • 1Xu R,Ebraheim NA,Ou Y,et al.Anatomic considerationsof pedicle screw placement in the thoracic spine.Roy-Ca-mille technique versus open-lamina technique[J].Spine,1998;23:1065-1068.
  • 2史亚民,侯树勋,韦兴,高天君,孙彦.青少年胸椎椎弓根影像学特征及其临床意义[J].中国矫形外科杂志,2003,11(21):1469-1472. 被引量:18
  • 3Kim YJ,LenkeLG,BridwellKH,et al.Free hand pediclescrew place-ment in the thoracic spine:is it safe[J].Spine,2004;29:333-342.
  • 4RampersaudYR,Pik JH,Salonen D,etal.Clinical accuracyof fluoro-scopic computer-assisted pedicle screw fixa-tion:a CT analysis[J].Spine,2005;30:183-190.
  • 5陆声,徐永清,李严兵,师继红,范泉水,郭海,石磊,成友华,张元智.脊柱椎弓根定位数字化导航模板的设计[J].中华创伤骨科杂志,2008,10(2):128-131. 被引量:43
  • 6王岩,毛克亚,张永刚,刘郑生,肖嵩华,刘保卫,王继芳,卢世璧.对徒手置入胸椎椎弓根螺钉的安全性评价[J].中国脊柱脊髓杂志,2006,16(8):596-599. 被引量:30
  • 7胡勇,谢辉,徐荣明,贾连顺,阮永平.青少年脊柱侧凸患者胸椎椎弓根螺钉置入的准确性和安全性评价[J].中国脊柱脊髓杂志,2006,16(11):820-824. 被引量:22
  • 8Carbone JJ,Tortolani PJ,Quartararo LG.Fluoroscopicallyassisted pedicle screw fixation for thoracic and thoraco-lumbar injuries.Technique and short-term complications[J].Spine,2003;28:91-97.
  • 9Kuntz C,Maher PC,Levine NB,et al.Prospective evalua-tion of thoracic pedicle screw placement using fluoroscopicimaging[J].J Spinal Disord Tech,2004;17:206-208.
  • 10DiSilvestre M,Parisini P,Lolli F,et al.Complications ofthoracic pedicle screws in scoliosis treatment[J].Spine,2007;32:1655-1661.

二级参考文献138

共引文献240

同被引文献165

引证文献8

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部