摘要 通过比较二阶微分火焰光谱法、离子色谱法和在线钠表法测量蒸汽中钠离子的准确性,检验了Orion、Swan、Polymetron等公司生产的蒸汽在线钠表的测量结果。表明:在保证仪表的最佳工况下,目前火电机组蒸汽在线钠表能够满足蒸汽中痕量钠离子准确测量的要求。在线钠表的测量准确性受电极性能、流体流速、碱化剂浓度、外界干扰等因素的影响,应定期对仪表进行清洁维护保养。 Through Comparison,the accuracy of sodium ions contained in steam measured by using sec- ond - order differential flame spectroscopic method,ion chromatographic method, and on - line sodium monitor method has been obtained,at the same time,the measured results by using on - line monitors manufactured from Orion, Swan, and Polymetron Corps being compared. Results show that the on - line sodium monitors can satisfy the requirement for accurately measuring the trace sodium ion con- tained in steam under condition Of ensuring the optimal work condition for said monitors. The measur- ing accuracy of on -line sodium monitors is affected by the electrode behavior, the flow speed of liquid, the concentration of alkalination agent, and the external interference etc., hence, cleaning, mainte- nance,and conservation for Said monitors should be periodically carried out.
出处 《热力发电》 CAS 北大核心 2012年第4期42-45,共4页 Thermal Power Generation
关键词 火电厂 蒸汽 痕量钠离子 在线钠表 准确性 误差检验 thermal power plant steam trace sodium ion on - line sodium monitor accuracy error in-spection
  • 相关文献

参考文献6

二级参考文献17

  • 1李永生 承慰才.FIA—TI—721型分光光度分析仪的研制[J].分析仪器,1986,(3):46-46.
  • 2Yong-Sheng Li, Xiu-Feng Gao. Flow injection analysis and application for chemistry analysis [ M ]. The Jilin People's Publisher, 2002.
  • 3E Bulska, M Walcerz,W Jedral,et al. On-line preconcentration of lead and cadium for flame atomic absorption spectrometry using a flow-through electrochemical microcell [J]. Anal. Chim. Acta, 1997,357: 133-140.
  • 4K A Johnson, D Kriz. Development of a three-electrode cell containing a polypyrrole coated auxiliary electrode [J ]. Instrumentation Science &Technology, 1997, 25( 1 ) :29-38.
  • 5BEVERLY NEWTOW.Innovative products and applications for the analysis of power waters using ion chromatography.1998 International Water Conference
  • 6第七届全国离子色谱学术报告会论文集[C].杭州.1999.10.
  • 7Dionex公司技术交流资料.离子色谱在电力工业系统的应用[R].1999.
  • 8王杏卿主编.热力设备的腐蚀与保护[M].北京:水利电力出版社.1998.