摘要
某电厂6号、7号机组锅炉烟尘排放浓度未满足<50mg/m3的标准要求,经对布袋除尘器和移动极板除尘器2种方案进行分析对比,认为6号机组改造为布袋除尘器、7号机组改造为移动极板除尘器可满足标准要求。
The smoke emission concentration of units no6 and no7 in one power plant can't reach the set standard of below 50 mg/m^3 ,it is intended to retrofit the electrostatic precipitator (EP). Through a- nalysis and comparation of two schemes,namely bag filter and dust remover with movable pole plate,it is believed that the bag filter is suitable to unit no6, and the dust remover with movable pole plate is suitable to unit noT. The indices of technical performane and economic efficiency in operation of above - mentioned two schemes after retrofitting have been given.
出处
《热力发电》
CAS
北大核心
2012年第4期69-71,共3页
Thermal Power Generation