摘要 以广州珠江城超高层大厦为例,结合施工过程定期对该楼23~27层外伸及带状钢结构桁架进行现场应力应变监测.同时,采用有限元软件ETABS中的顺序施工模块功能,对该楼模型进行施工过程数值模拟分析.监测结果表明:钢结构是安全的;模拟分析理论值与实测数据吻合较好,表明有限元模拟分析计算模型和方法的正确性.研究成果可作为广州珠江城大厦安全施工控制方面的一项重要评估指标,同时对同类工程具有参考价值. Taking the Pearl River Building in Guangzhou as an example,the on-site construction health monitoring system was established during its construction stage.The stress and strain measurements on the key elements of outrigger and belt trusses between the 23-27 floors of the building were conducted.Meanwhile,the finite element software ETABS was utilized to conduct the numerical structural analysis for construction simulation during its different construction stages.Comparison between field measurement and numerical analysis showed that numerical simulation results have good agreements with the measured data,which indicated that the proposed construction mechanics analysis procedures in this paper are valuable for the construction monitoring and control for this super tall building.The method could also be used as the practical references for the similar high-rise buildings' design and construction.
出处 《广州大学学报(自然科学版)》 CAS 2012年第2期36-42,共7页 Journal of Guangzhou University:Natural Science Edition
基金 国家自然科学基金项目(50778082 51078096) 广东省国际科技合作项目(2009B050200015)资助
关键词 超高层结构 施工监控 施工模拟 时变结构分析 super high-rise building construction health monitoring construction simulation time-dependent structural analysis
  • 相关文献

参考文献6

二级参考文献18

共引文献322

同被引文献49

  • 1陈志华,牛犇,张智升.天津图书馆钢结构关键节点应力监测分析[J].工业建筑,2015,45(2):154-158. 被引量:7
  • 2王刚,姚谦峰.环境激励下框架结构体系的模态识别方法研究[J].工业建筑,2004,34(12):45-47. 被引量:7
  • 3刘学武,郭彦林,张庆林,刘禄宇.CCTV新台址主楼施工过程结构内力和变形分析[J].工业建筑,2007,37(9):22-29. 被引量:46
  • 4Chowdhary P, Sharma R K. Evaluation of creep and shrinkage effects in composite tall buildings [ J ]. The Structural Design of Tail and Special Buildings, 2011, 20 ( 7 ) : 871 -880.
  • 5Ellobody E, Young B. Numerical simulation of concrete encased steel composite columns [ J ] . Journal of Constructional Steel Research, 2011, 67(2) :211-222.
  • 6Brownjohn J M W. Structural health monitoring of civil infrastructure[ J]. Philosophical Transactions of the Royal Society A, 2007,365 ( 1851 ) :589-622.
  • 7Dundar C, Tokgoz S, Tanfikulu A K, et al. Behavior of reinforced and concrete-encased composite columns subjected to biaxial bending and axial load [ J ]. Building and Environment, 2008, 43(3) :1109-1120.
  • 8Fintel M, Ghosh S K, Iyengar H S. Column shortening in tall buildings-prediction and compensation [ M ]. Engineering Bulletin No. EBIO8D. PCA: Washington DC, 1987.
  • 9ACI Committee 209. ACI 209R-92 Prediction of creep, shrinkage and temperature effects in concrete structures [ R ]. American Concrete Institute: Farmington Hills MI, 1997.
  • 10Comite Euro-intemational Du Beton. CEB-FIP model code [ S]. London: Thomas Telford Publishing, 1993.

引证文献6

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部