期刊文献+

Determination of trace heavy metals in milk using an ionic liquid and bismuth oxide nanoparticles modified carbon paste electrode 被引量:2

Determination of trace heavy metals in milk using an ionic liquid and bismuth oxide nanoparticles modified carbon paste electrode
原文传递
导出
摘要 A novel carbon composite electrode modified with bismuth oxide nanoparticles and the ionic liquid n-octylpyridinium hexafluorophosphate was fabricated and used to simultaneously determine cadmium and lead levels using square wave anodic stripping voltammetry.This electrode combines the unique advantages of nanomaterials and ionic liquid with the low cost and easy fabrication of the carbon composite electrode.Compared with the traditional binder based composite electrode,our electrode exhibited well-defined and separate stripping voltammetric peaks for cadmium and lead.Furthermore,the antifouling capacity of the bismuth film electrode was significantly improved by the ionic liquid.Under optimized conditions,the linear range of the composite electrode was from 3.0 to 30.0 μg L-1 for both metal ions with a detection limit of 0.15 μg L-1 for cadmium and 0.21 μg L-1 for lead.Trial milk sample analyses showed that the modified electrode was sensitive,reliable and effective for the determination of trace heavy metals,holding great promise for routine analysis applications. A novel carbon composite electrode modified with bismuth oxide nanoparticles and the ionic liquid n-octylpyridinium hexafluorophosphate was fabricated and used to simultaneously determine cadmium and lead levels using square wave anodic stripping voltammetry. This electrode combines the unique advantages of nanomaterials and ionic liquid with the low cost and easy fabrication of the carbon composite electrode. Compared with the traditional binder based composite electrode, our electrode exhibited well-defined and separate stripping voltammetrie peaks for cadmium and lead. Furthermore, the antifouling capacity of the bismuth film electrode was significantly improved by the ionic liquid. Under optimized conditions, the linear range of the composite electrode was from 3.0 to 30.0 μg L^-1 for both metal ions with a detection limit of 0.15 μg L^-1 for cadmium and 0.21μg L^-1 for lead. Trial milk sample analyses showed that the modified electrode was sensitive, reliable and effective for the determination of trace heavy metals, holding great promise for routine analysis applications.
出处 《Chinese Science Bulletin》 SCIE EI CAS 2012年第15期1781-1787,共7页
基金 supported by the National High Technology Research and Development Program of China (2011AA100704)
关键词 修饰碳糊电极 微量重金属 离子液体 同时测定 纳米粒子 牛奶样品 氧化铋 碳纤维复合材料 heavy metals, bismuth oxide nanoparticles, ionic liquid, carbon paste electrode, milk
  • 相关文献

参考文献32

  • 1Grze I M. Ants and heavy metal pollution—A review. Eur J Soil Biol,2010,46: 350-355.
  • 2Wu G,Kang H B,Zhang X Y,et al. A critical review on the bio-removal of hazardous heavy metals from contaminated soils: Issues,progress,eco-environmental concerns and opportunities. J Hazard Mater,2010,174: 1-8.
  • 3Wei B G,Yang L S. A review of heavy metal contaminations in urban soils,urban road dusts and agricultural soils from China. Microchem J,2010,94: 99-107.
  • 4Puschenreiter M,Horak O,Friesl W,et al. Low-cost agricultural measures to reduce heavy metal transfer into the food chain —A review. Plant Soil Environ,2005,51: 1-11.
  • 5Brainina K Z,Malakhova N A,Stojko N Y. Stripping voltammetry in environmental and food analysis. Fresenius J Anal Chem,2000,368: 307-325.
  • 6Karadjova I,Izgi B,Gucer S. Fractionation and speciation of Cu,Zn and Fe in wine samples by atomic absorption spectrometry. Spectroc Acta Pt B,2002,57: 581-590.
  • 7Chuparina E V,Aisueva T S. Determination of heavy metal levels in medicinal plant Hemerocallis minor Miller by X-ray fluorescence spectrometry. Environ Chem Lett,2011,9: 19-23.
  • 8Alison M G,Andrew C C,Geoffrey R S. Determination of free and total copper and lead in wine by stripping potentiometry. Fresenius J Anal Chem,1997,358: 711-717.
  • 9Economou A. Bismuth-film electrodes: Recent developments and potentialities for electroanalysis. TrAC Trends Anal Chem,2005,24: 334-340.
  • 10Tesarovaa E,Baldrianovaa L,Hocevar S B,et al. Anodic stripping voltammetric measurement of trace heavy metals at antimony film carbon paste electrode. Electrochim Acta,2009,54: 1506-1510.

同被引文献11

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部