根据植入式心脏起搏器的国际标准,对标准中要求的静磁场测试线圈进行了设计。检验结果标明,设计的线圈能用于植入式心脏起搏器的静磁场测试。
Based on the international standards about implantable pacemakers, designing the static magnetic field testing coil in accordance with the requirements of the standards. The testing result demonstrates that the designed coil could be used for the static magnetic field strength test of implantable pacemakers.
出处
《中国医疗器械杂志》
CAS
2012年第3期182-184,共3页
Chinese Journal of Medical Instrumentation
关键词
心脏起搏器
静磁场
线圈
pacemaker, static magnetic field, test