摘要
本文依据某厂600MW烟煤锅炉设备设计参数和相关的煤质分析数据,通过理论计算分析,给出该烟煤锅炉掺烧一定比例褐煤的实际烟气量,结合运行使用情况进行引风机改造选型计算分析。
As per the design parameters and relational coal analysis data of a 600MW bituminous boiler, actual flue gas flow of the boiler burning mixed with a certain proportion of lignite is provid- ed, as well as calculation analysis of renovation and type choice of induced fan combined with the operation instance.
出处
《锅炉制造》
2012年第3期14-16,共3页
Boiler Manufacturing
关键词
锅炉
烟气量
引风机
计算
boiler
flue gas flow
induced fan
calculation