摘要 基于模糊数学的隶属度概念,从节点的弹性位移着手实现节点的模糊转角,推导了空间弹性梁单元的单刚矩阵,给出了模糊转角位移的隶属度与弹簧刚度的映射关系。同时考虑了连接节点的滑移,导出了有滑移杆件的轴向刚度。借助MATLAB软件,编制了考虑滑移的空间弹性节点模型(SFJS)源程序。利用该程序分析了JJ3型送电线路铁塔在支座不均匀沉降作用下主材和斜材的轴向力分布规律,数值计算结果与足尺铁塔试验结果吻合良好。相比传统的刚架模型,考虑滑移的空间弹性节点模型计算结果更能准确地反映地表变形作用下送电线路铁塔杆件的内力。分析结果可以为采动区送电线路铁塔的设计、计算和保护提供理论依据。 Based on the fuzzy membership degree theory, fuzzy rotation angle of joint is provided in terms of its flexible displacement. The element stiffness matrix of space flexible beam and the relationship between fuzzy rotation and spring stiffness were derived based on the concept of fuzzy rotation angle of joint. The axial stiffness of truss member was presented considering the effect of connection slippage. Program of space flexible joint model with the function of analyzing slippage of joints (SFJS) was developed in MATLAB. SFJS is used to obtain the axial force of legs and diagonals of JJ3-type transmission line steel tower. The numerical results and full-scale test results matched fairly well. By means of the space flexible joint model with slippage, the internal force distribution in the bar of transmission line steel tower can be solved more accurately than the traditional space frame model. The SFJS provides theoretical foundation for design, calculation and protection of transmission line steel tower located in mining areas. Compared with the traditional modal of space truss, SFJS can calculate more accurately the internal force of truss members induced by the deformation of foundation
出处 《工程力学》 EI CSCD 北大核心 2012年第6期292-299,共8页 Engineering Mechanics
基金 国家自然科学基金面上项目(50774081) 教育部新世纪人才支持计划项目(NCET-07-0804) "十一五"国家科技支撑计划重点项目(2006BAJ14B07 2006BAJ05A08)
关键词 送电线路铁塔 空间弹性节点 连接滑移 模糊转角 地表变形 transmission line steel tower space flexible joint connection slippage fuzzy rotation surfacedeformation
  • 相关文献

参考文献9

  • 1Knight G M S, Santhakumar A R. Joint effect on behavior of transmission towers[J]. American Society of Civil Engineers, 1993, 119(3): 698-712.
  • 2Ungkurapinan N. A study of joint slip in galvanized bolted angle connections[D]. Canada: Canada University of Manitoba, 2000.
  • 3Ungkurapinan N, Chandrakeerthy S R, Rajapakse R K N D, et al. Joint slip in steel electric transmission towers[J].Engineering Structures, 2003, 25: 779-788.
  • 4Kroeker D. Structural analysis of transmission towers with connection slip modeling[D]. Canada: Canada University of Manitoba, 2001.
  • 5Kitipornchai S, Al-Bermani F, Kang W J, et al. Some practical aspects of modeling lattice towers[C]. Proceedings of the Fourth International Conference on Advances in Steel Sturctures: Volume 1. Shanghai: Tongji University Press, 2005: 369-375.
  • 6隋允康,潘天群.结构节点模型的“弗晰”精化处理[J].计算结构力学及其应用,1989,6(3):45-51. 被引量:9
  • 7隋允康,丁殿明.结构节点的中介状态对力学分析和优化设计的影响[J].上海力学,1992,13(2):6-12. 被引量:1
  • 8曾宪文,李新民,刘士彬.弹性节点的模糊分析及其在输电铁塔中的应用[J].东北电力学院学报,2000,20(1):25-29. 被引量:1
  • 9肖圣燮, 王平义, 吕恩琳. 模糊数学在土木与水利工 程中的应用[M]. 北京: 人民交通出版社, 2004.

二级参考文献7

  • 1线令希.关于结构优化设计中的主观信息[J]计算结构力学及其应用,1985(02).
  • 2()库 克(Cook,R.D.)著,程耿东等.有限元分析的概念和应用[M]科学出版社,1989.
  • 3隋允康,黄秀芬.改进的梯度投影单纯形法GPS及其在桁架优化上的应用[J]大连工学院学报,1988(01).
  • 4隋允康.梯度投影单纯形法及其应用[J]固体力学学报,1986(01).
  • 5隋允康,周志隆.规划法和准则法一类问题的统一解法[J]上海力学,1986(01).
  • 6隋允康,耿树森.Taylor展式的推广及其在求解数学规划中的应用[J]工程数学学报,1985(01).
  • 7隋允康,潘天群.结构节点模型的“弗晰”精化处理[J].计算结构力学及其应用,1989,6(3):45-51. 被引量:9

共引文献8

同被引文献42

  • 1代泽兵,鲁先龙,程永锋.煤矿采空区架空输电线路基础研究[J].武汉大学学报(工学版),2009,42(S1):312-316. 被引量:15
  • 2王朋,高康,黄伟东,陈海波,张会武.螺栓滑移对格构式结构静动态特性的影响研究[J].固体力学学报,2013,34(S1):211-215. 被引量:9
  • 3张建强,杨昆,王予东,汤跃超.煤矿采空区地段高压输电线路铁塔地基处理的研究[J].电网技术,2006,30(2):30-34. 被引量:60
  • 4DL/T5440-2009.重覆冰架空输电线路设计技术规程[S].
  • 5GB50545-2010,110KV-750kV架空输电线路设计规范[S].
  • 6中国电力工程顾问集团西南电力设计院.重冰区双回路输电线路研究总报告[R].成都:西南电力设计院,2008.
  • 7重庆大学,中国电力工程顾问集团西南电力设计院.重冰区输电线路脱冰动力响应研究报告[R].重庆:重庆大学,2008.
  • 8Ungkurapinan N.A study of joint slip in galvanized bolted angle connection[D].Winnipeg,Manitoba,Canada:University of Manitoba,2000.
  • 9Ungkurapinan N,Chandrakeerthi R,Rajapakse R K N D,et al.Joint slip in electrical transmission towers[J].Engineering Structures,2003,25 (6):779-788.
  • 10Ahmed K I E,Rajapakse R K N D,Gadala M S.Influence of bolted-joint Slippage on the response of transmission towers subjected to frost-heave[J].Advances in Structural Engineering,2009,12(1):1-17.

引证文献5

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部