简单阐述了经消弧线圈接地系统的特性,描述了在ATP下的电弧模型,并应用ATP搭建模型,仿真分析中性点非直接接地系统在不同故障情况下的特征,最终应用仿真图形充分验证了中性点经消弧线圈接地系统的主要特性。
This paper briefly expounds the characteristic of system with grounding via Peterson coil, describes the arc model in the ATP, and applies ATP to build simulation model, analyses characteristics of different failure situation on neutral indirect grounding system, finally, takes use of simulative pictures to verify main characteristics of the system with grounding via Peterson coils.